Husky HD1500 warranty Maintenance, Servicing a DOUBLE- Insulated Appliance

Page 17

English

6.0MAINTENANCE

6.1CONNECTIONS

Connections on pressure washer hoses, gun and spray wand should be cleaned regularly and lubricated with light oil or non-water soluble grease to prevent leakage and damage to the o-rings.

6.2NOZZLE

Clogging of the nozzle causes the pump pressure to be too high and cleaning is immediately required.

1.Clear the nozzle by forcing a stiff wire through center hole.

2.Backflush the nozzle with water.

3.Reconnect the nozzle to the wand.

6.3LUBRICATION

The pressure washer is designed with a permanent lubrication system. Conventional oil check and oil changes are not necessary.

NOTE: IN CASE OF OIL LEAKAGE, CONTACT THE CUSTOMER SERVICE DEPARTMENT CONCERNING REPAIR. A SMALL AMOUNT OF OIL LEAKAGE IS NORMAL. www.huskypowerwasher.com.

6.4WATER SCREEN

The pressure washer is equipped with a water inlet screen filter to protect the pump.

CAUTION: If the screen is not kept clean, the flow of water to the pressure washer will be restricted and the pump may be

CAUTION damaged.

￿To clean inner water screen, remove the inlet nipple and remove the filter screen from the inlet.

￿Backflush screen to clean.

￿Replace screen and inlet nipple immediately to pre- vent any foreign matter from entering the pump.

CAUTION: Do not damage the screen while removing or cleaning. Any foreign particles entering the pump may damage

CAUTION the pump.

6.5COOLING SYSTEM

The air vents, located in and around the pressure washer, must be kept clean and free of any obstruc- tions to ensure proper air cooling of the motor during operation.

WARNING: Prevent water from pene- trating the vents of the pressure washer to minimize the risk of damage to the

WARNING machine and to reduce the risk of shock to the operator.

7.0SERVICING A DOUBLE- INSULATED APPLIANCE

In a double-insulated product, two systems of insulation are provided instead of grounding. No grounding means is pro- vided on a double-insulated product, nor should a means for grounding be added

to the pressure washer. Servicing a double-insulated product requires extreme care and knowledge of the system, and should be done only by qualified service personnel.

Replacement parts for a double-insulated product must be identical to the parts they replace. A double- insulated product is marked with the words “DOUBLE- INSULATION” or “DOUBLE-INSULATED”. The symbol above may also be marked on the product.

17

Image 17
Contents Operator’s Manual Manual del Usuario Manuel de l’opérateur Serial Number 200Mounting bracket is designed for use with HD 1500 Hsds only Moving and Storage InstructionsEnglish Store high pressure cleaner on the docking station as shown Assembly InstructionsParts Drawing Spray Gun Variable Nozzle with Lance Parts List FigIndex Connect the Garden Hose Remove the Water Plug Connect the High Pressure Hose1010 Connect to Water Supply Insert the Wand Into the Spray GUN1111 Turn on Water Supply Start the Pressure WasherGROUND-FAULT CIRCUIT-INTERRUPTER PRO- Tection Important Safety InstructionsAutomatic Total STOP→ Motor OverloadOperating Connections Power Supply ConnectionHigh Pressure Hose Extension CordsVariable Spray Nozzle START-UP ProcedureOperating Instructions English USE of Detergent Cleaning TechniquesApplication of Detergent Application of Liquid Vehicle WAXServicing a DOUBLE- Insulated Appliance MaintenanceProblem or Concern Possible Cause Solution TroubleshootingNever use Bleach, Ammonia or Hot Water in the unitUnit Water Water leaking anywhere from the Manifold Manifold Assembly is leakingPump housing is leaking water Ensure that there are no kinks in the HoseHuskypowerwasher.com Wand Removing @huskypowerwasher.comWand Attaching To attach the Wand apply some moderate 10% Max Technical DataLimited Warranty Implied Warranties HOW to Obtain Warranty ServiceNúmero de Serie ImportanteInstrucciones Para Movilizar Y Almacenar EL Equipo Español Instrucciones DE Montaje Diseño Piezas Lista Piezas Fig Pag ÍndiceConecte LA Manguera DE Alta Presión Extraiga EL Tapón DEL AguaConecte LA Manguera Para JardínIntroduzca EL Tubo EN LA Pistola Rociadora Conecte CON EL Suministro DE AguaEspañolñol Sobrecarga DEL Motor Importantes Instrucciones DE SeguridadGuarde Estas Instrucciones Atención Conexión apropiada del agua Conexiones OperativasEmpalme DE LA Alimentación Eléctrica ExtensionesBoquilla Chorro Regulable Instrucciones DE USOProcedimiento DE Puesta EN Marcha Español Técnicas DE Limpieza USO DEL DetergenteAplicación DEL Detergente Aplicación DE LA CeraManutención DE UN Equipo CON Doble Aislamiento MantenimientoPowerwasher.com Problema Causas Posibles SoluciónLocalización DE LAS Averías Niaco o agua caliente en la unidadSher.com En customerservice@huskypowerwaNosotros encustomerservice@huskyp Erservice@huskypowerwasher.com En una proporción igual a la de la manguera El tubo no funciona correctaDel jardín Conectar el tuboPresión bomba Psi 102,4 bar Datos TécnicosDel jabón 10% max Garantía limitadaCómo Obtener EL Servicio Garantía Date d’achat Instructions DE Deplacement ET Entreposage Français Instructions DE Montage Illustration DES Pièces Pièces Fig Contents Branchez LE Tuyau D’ARRO- Sage Pour UNE Installation SimpleBranchez AU Robinet Insérez LA Lance Dans LE Pistolet Français Conserver CES Instructions Instructions Importantes DE SecuriteSurcharge DU Moteur Protection PAR Disjoncteur DE Fuite À LA TerreRallonges InstallationBranchement DE L‘ALIMENTATION Électrique Lance Avec Tête Réglable Mode D’EMPLOIMise EN Marche Français Techniques DE Nettoyage Utilisation DE DétergentsApplication DE Détergents Application DE Cire Liquide Pour VéhiculesEntretien D’UN Appareil a Double Isolation EntretienGuide DE Dépannage Probleme Cause Possible Solution’ensemble collecteur fuit Ouvert ou l’unité ne reçoit pas un Plein volume d’eauTie inférieure de l’unité Com pour une assistance techniqueRservice@huskypowerwasher.com Correctement Ne s’arrête pas lorsque laRosage Lance BranchementBar 6,82 bar Données TechniquesSi des pièces sont manquantes ou endomma Garantie limitéeFrançais 2005 cod. PLDCxxxxx REV