START-UP CHECKLIST FOR FAN-ASSISTED
RAYPAK PRODUCTS
This
GAS SUPPLY DATA |
| CLEARANCES |
|
Regulator Model & Size | _________ / ______CFH | Front Clearance | _______________In. |
Gas Line Size (in room) | ________________In. NPT | Right Side Clearance | _______________In. |
Length of Gas Line | ________________Eq Ft | Left Side Clearance | _______________In. |
Low Gas Pressure Setting | ________________In. WC | Rear Clearance | _______________In. |
High Gas Pressure Setting | ________________In. WC | Overhead Clearance | _______________In. |
Gas | ________________ |
|
|
( Ball, Lube cock) |
| ELECTRICAL |
|
Sediment Trap | ________________Y/N | Voltage Supply (VAC) | No Load______ Load_____ |
Port | _______Std______Full | Voltage | _______________VAC |
|
| Voltage Com to Ground | _______________VAC |
VISUAL INSPECTION OF COMPONENTS | Hot Surface Igniter | _______________Ohms | |
Verify inspection was done and condition of components are in | Auto High Limit Setting | _______________deg F | |
good working order with a “yes” |
| Manual Reset High Limit Setting | _______________deg F |
Wiring Harness | _________________ Y/N | Operating Control Setting | _______________deg F |
Burner/s (flame) | _________________ Y/N |
|
|
Refractory (visual) | _________________ Y/N | Sketch plumbing on reverse side |
|
Remote flame sense | _________________ Y/N | WATER SUPPLY |
|
Covers in place for outdoor | _________________ Y/N | Flow Rate in GPM or Delta T | _______________If Avail |
|
| Measure flow rate at full fire |
|
VENTING |
| Pump Economaster setting | _______________Minutes |
Vent Size: _____________ | Stack Height:_______ | Low Water Cutoff | _______________Test |
Category: _________ | sketch vent on reverse side *** | Number of Tanks and Size | Qty____ _______Gallons |
Vent Material: | __________________ | Plumbing Size | _______________ |
Vent Termination Type: | __________________ | Pump Size: _________(boiler) | Pump HP: ______ |
Combustion Air Openings: | Low __________ in2 | Impeller trim____________ | Pump Model___________ |
Ventilation air | High __________ in2 | Louvers __________________ | Screens________________ |
EMISSIONS SETTINGS AND TEST INFORMATION | Nominal Factory Recommended Settings | ||
(AT FULL FIRE) |
|
| |
Blower Pressure Setting | _________________In. WC | See manual or card tag |
|
Supply Gas Pressure | _________________In. WC | See manual or card tag |
|
Verify stable pressure static & | dynamic condition |
|
|
Pilot Gas Pressure | _________________In. WC | See manual or card tag |
|
Manifold Gas Pressure | _________________In. WC | See manual or card tag |
|
The following measurements must be obtained with a Combustion Analyzer. |
| ||
NOX | _________________PPM | Less than 20 PPM (If required by Certifying Agency) | |
Free Oxygen | _________________% | See manual |
|
CO | _________________PPM | Less than 150 PPM |
|
CO2 | _________________% | See manual |
|
Model Number: ______________________________
***Note: draw venting with details, such as extractors, barometric dampers, blast dampers or draft inducers
Serial Number: _______________________________
Site Altitude Above Sea Level __________________Ft.
Job Name _______________________________________________________________________________________
Address _________________________________________________________________________________________
Physical Location of Boiler: Indoors______; Outdoors______; Ground Level______; Roof______; Below Grade______
Mechanical Contractor / Installer _______________________________________________________________________
Date and Time of
Information must be faxed to: (805)