Carrier 69UG15 manual Condition Possible Cause Reference Section, Engine Will Not Shut Off

Page 25

 

 

REMEDY/

CONDITION

POSSIBLE CAUSE

REFERENCE

 

 

SECTION

3.1.3 Engine Will Not Shut Off

 

 

 

 

 

Engine will not shut off

Loose ground connection

Clean/Tighten

Improperly seated fuel solenoid

Correct

 

 

 

 

3.1.4 Starter Motor Malfunction

 

 

 

 

 

 

Battery insufficiently charged

Charge

 

Battery cable connections loose or oxidized

Check/Replace

 

Battery cables defective

Check/Replace

Starter motor will not crank or turns

Starter brushes shorted out

Engine Manual

slowly

Starter brushes hang up, defective or have no contact

Engine Manual

 

Starter solenoid damaged

Engine Manual

 

Ignition switch defective

Replace

 

Engine lube oil too heavy

Section 1.10.f.

 

 

 

Starter motor turns, but pinion does

Pinion or ring gear obstructed or worn

Engine Manual

not engage

 

 

 

 

 

Starter motor does not disengage

Ignition switch is bad

Check/Replace

after switch has been released

Starter motor solenoid is bad

Engine Manual

 

 

 

Pinion does not disengage after

Starter is bad

Engine Manual

engine is running

 

 

 

 

 

3.1.5 Malfunction In The Engine Starting Circuit

 

 

 

 

No power to starter motor solenoid

Battery defective

Correct

Loose electrical connections

Tighten

 

 

 

 

 

Battery defective

Correct

 

Loose electrical connections

Tighten

 

Oil pressure switch defective

Section 1.8

Fuel solenoid does not energize or

Water temperature safety switch open

Section 1.8

Fuel solenoid defective

Engine Manual

does not remain energized

Intake heater switch is bad

Check

 

 

Electronic governor module is bad

(Engine Manual)

 

Replace

 

 

 

 

(Section 4.4.15)

 

 

Check/Replace

 

 

 

 

Intake heater switch is bad

Section 4.4.15

Intake heater does not energize

Timer is bad

Section 4.4.15

Heater element is bad

Section 4.4.15

 

 

Heater relay is bad

Section 4.4.15

 

 

 

T-343

3--2

Image 25
Contents Operation and Service Model 69UG15 Table of Contents Table of Contents List of Tables List of IllustrationsTable Number Safety Summary Specific Warning and Caution Statements Section Description Configuration IdentificationIntroduction PID Generator Set Volt343 Engine Screw Threads EngineOperating Controls and Instruments Battery ChargerIntroduction Control Panel and Related Components a. Gauges and SendersSafety Devices Manual SwitchesMeters Customer Specific Control Panel and Box Auto Restart Sequencing Auto Restart Preset Values Indicator DescriptionIntake Engine Series FuelAuto Restart Sequencing Intake Engine Series Intake Heater Unit SpecificationsGenerator Nominal Tank Sizes Fill Capacity Draw CapacityEngine Data Outdoor Temperature CentigradeSAE Winter SummerOperation Generator SET InstallationGenerator SET Removal Typical Generator Set Mounting Quick MountCold Engine Preheat Times Starting and Stopping InstructionsControl Circuit Operation Remedy Section TroubleshootingCondition Possible Cause Reference Section Diesel Engine Engine Will Not StartEngine Will Not Shut Off Condition Possible Cause Reference SectionStarter Motor Malfunction Malfunction In The Engine Starting CircuitBattery Charger Solid State Miscellaneous Engine TroubleshootingAlternating Current Generator Auto RE-START Option Remedy Preventative Maintenance Schedule Section Service and Preventive MaintenanceBattery Service Units Interval Units Description of ProcedureEvery 1000Hours Interval UnitsServicing Heater Switch 1. Remove control box cover Servicing Low Oil Pressure SwitchAttempt to Adjust Engine Speed Engine Crankcase Breather Preventative Maintenance and Operating PrecautionsServicing the Alternating Current Generator CoolingWinding Insulation Testing Terminal Strip CleaningWire Ohm Rotor DamageBearing Replacement Diode TestingTerminals see Figure Bolt Isolator Truss Frame UnidriveGenerator Install Mount With Large Flare AT TOP Frame Engine Isolator/Shockmount ReplacementBolt Shockmount Engine & Generator SHOCKMOUNTS/ISOLATORS TOP View Unidrive Torque RequirementsEngine Mount Right Side View Schematic Diagram Legend Section SchematicsSchematic Diagram Schematic Diagram 460 Volt Alternating Current Generator Schematic Diagram 230 Volt Alternating Current Generator Based On Drawing 62-11413-00 Rev a Schematic Diagram Schematic Diagram 460 Volt Alternating Current Generator Index Index