Briggs & Stratton 30244 Engine Technical Information, Product Specifications

Page 15

SPECIFICATIONS

ENGINE TECHNICAL

INFORMATION

This is a single cylinder, overhead valve(OHV), air cooled engine. It is a low emissions engine.

In the State of California, this type of engine is certified by the California Air Resources Board to meet emissions standards for 1000 hours. Such certification does not grant the purchaser, owner or operator of this engine any additional warranties with respect to the performance or operational life of this engine.The engine is warranted solely according to the product and emissions warranties stated elsewhere in this manual.

PRODUCT

SPECIFICATIONS

Generator Specifications

Starting Wattage

13,500 Watts

Wattage

8,000 Watts

Rated AC Load Current:

 

At 120 Volts

. .66.6 Amps

At 240 Volts

. .33.3 Amps

Phase

. . . .1–phase

Rated Frequency

. . .60 Hertz

Shipping Weight

. . . . .240 lbs.

Emissions Compliance Period

This engine is certified to meet the United States Environmental Protection Agency (USEPA) Phase 2 emission standards. For phase 2 certified engines, the Emissions Compliance Period referred to on the Emissions Compliance label indicates the number of operating hours for which the engine has been shown to meet Federal emission requirements. For engines less than 225 cc displacement, Category C = 125 hours, B = 250 hours and A = 500 hours. For engines of 225 cc or more, Category C = 250 hours, B = 500 hours and A = 1000 hours.

This engine has an Air Index of 3.The EPA Emissions compliance period is Category A.The displacement of this engine is 407 cc.

Engine Specifications

Rated Horsepower . . . . . . . . . . . . . . . . . . . 15 at 3600 rpm Bore . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 mm Stroke . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 mm Displacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 407 cc Spark Plug

Type: . . . . . . . . . . . . Champion RC14YC or Equivalent

Set Gap To: . . . . . . . . . . . . . . . . . . 0.030 inch (0.76 mm)

Valve clearance with valve springs installed and piston is at top dead center (check when engine is cold).

Intake . . . . . . . . . . . . . . . . . 0.002-0.004 in. (0.05-0.10 mm) Exhaust . . . . . . . . . . . . . . . . 0.002-0.004 in. (0.05-0.10 mm) Fuel Capacity . . . . . . . . . . . . . . . . . . . . . . . . . 7 U.S. gallons Oil Capacity (with oil filter) . . . . . . . . . . . . . . . . . . 51 fl. oz. Oil Type:

Above 40° F . . . . . . . . . . . . . . . . . . .SAE 30 or 10W-30 Below 40° F . . . . . . . . . . . . . . . .SAE 5W-30 or 10W-30

15

Image 15 Contents
Starting Watts Operator’s Manual Manual del OperarioCall Generator Helpline Llame Línea Directa del Generador Table of Contents Safety RulesEquipment Description When Transporting or Repairing Equipment When Adding or Draining FuelWhen Starting Equipment When Operating EquipmentWhen Testing for Engine Spark When Adjusting or Making Repairs to Your GeneratorKnow Your Generator Electric Start AssemblyCheck Battery / Attach Negative Battery Wire To installAdd Fuel When Adding FuelBefore Starting the Engine Add Engine OilGenerator Location Using the GeneratorConnecting to a Building’s Electrical System System GroundStarting the Engine Operating GeneratorLow Oil Pressure Shutdown System Connecting Electrical LoadsReceptacles Stopping the EngineGround Fault Protection 120/240 Volt AC, 30 Amp, Locking ReceptacleVolt AC, 15 Amp, Gfci Duplex Receptacles HOW to USE the Battery Charger Testing the GfciGenerator Adapter Cord SET Cold Weather Operation Creating a Temporary Cold Weather ShelterCreating a Permanent Cold Weather Shelter Example Power ManagementDont Overload Generator CapacityEngine Technical Information Product SpecificationsGenerator Specifications Engine SpecificationsGenerator Maintenance Generator CleaningGeneral Recommendations Oil Engine MaintenanceBattery Maintenance Fuel Valve MaintenanceChanging Engine Oil and Oil Filter Service Air CleanerTo clean or replace air cleaner components Adding Engine OilClean/Replace Spark Plug Clean Spark Arrester ScreenClean and inspect the spark arrester as follows To adjust valve clearance Service AdjustmentsChecking/Adjusting Valve Clearance Carburetor AdjustmentsTighten Jam Nut to 175 inch-pounds 19.7 N-m Generator StorageLong Term Storage Instructions Protect Fuel SystemTroubleshooting Page Your Warranty Rights and Obligations Emissions Control Warranty Statement Emission Warranty Parts List This Warranty Shall not Apply to the Following Warranty is not TransferableLimited Warranty Advertencia Tabla DE ContenidosDescripción DEL Equipo Reglas DE SeguridadCuando Transporte O Repare EL Equipo Cuando Añada Combustible O Vacíe EL DepósitoCuando Ponga EN Funcionamiento EL Equipo Cuando Opere EL EquipoPrecaución Cuando Ajuste O Haga Reparaciones a SU GeneradorCuando Pruebe LA Bujía DEL Motor Conozca SU Generador Tomacorriente Gfci Dobles de 120 Voltios AC, 15 AmpTomacorriente con Dispositivo de Seguridad de Para instalar MontajeArranque Eléctrico Desembalaje del GeneradorCuando Añada Combustible Antes DE Darle Arranque AL MotorAgregar Aceite al Motor Agregue CombustibleUbicación del Generador USO DEL GeneradorTierra del Sistema Conexión al Sistema Eléctrico de un EdificioEncienda el Motor Operando EL GeneradorParado Del Motor Sistema DE Parada POR Baja Presion DEL AceiteReceptáculos Conexion De Cargas Electricas120/240 Voltios AC, 30 Amp, Receptáculo de Seguridad Volt AC, 15 Amperios, Gfci Receptáculo DoblesProtección Contra Fallos de Conexión a Tierra Juego DE Cables DEL Adaptador DEL Generador Cargador DE BateríaComprobación del Gfci Figura 32 Clima Frío Estructura de Protección Operación Durante UN Clima FríoEjemplo No Sobrecargue GeneradorCapacidad Control de la EnergíaEspecificaciones del Generador Información Técnica Sobre EL MotorEspecificaciones DEL Producto Período de Cumplimiento del MotorRecomendaciones Generales Mantenimiento DEL GeneradorLimpieza del Generador Aceite Mantenimiento DEL Motor AdvertenciaMantenimiento de la Batería Mantenimiento de la Válvula de CombustiblePara limpiar o sustituir el filtro de aire componentes Proporcione Servicio al Depurador de AireAdición de Aceite del Motor Cambio de Aceite del Motor y Filtro de AceiteLimpie/Reemplace la Bujía Limpie la Pantalla ApagachispasLimpie e inspeccione el apagachispas de la siguiente manera Ajuste de la Separación de las Válvulas Revisiones Y AjustesVelocidad del Motor Ajustes del CarburadorGenerador AlmacenamientoAlmacenamiento Para Periodos Prolongados Proteja el Sistema de CombustibleDiagnositicos DE Averías Problemo Causa AccionDerechos Y Obligaciones DE LA Garantía Garantía DE Control DE Emisiones EGR Notas Esta Garantía no SE Aplicará EN LOS Siguientes Casos Generac Power SYSTEMS, INCPlan DE Garantía Aplicaciones DE CONSUMO/COMERCIALES/INDUSTRIALESUso comercial Uso del consumidor