Briggs & Stratton 30244 operating instructions When Adjusting or Making Repairs to Your Generator

Page 4

SAFETY RULES

WARNING

Rapid retraction of starter cord (kickback) will pull hand and arm toward engine faster than you can let go.

Broken bones, fractures, bruises or sprains could result.

When starting engine, pull cord slowly until resistance is felt and then pull rapidly to avoid kickback.

NEVER start or stop engine with electrical devices plugged in and turned on.

WARNING

Running engines produce heat.Temperature of muffler and nearby areas can reach or exceed 150°F (65°C).

Severe burns can occur on contact.

Exhaust heat/gases can ignite combustibles, structures or damage fuel tank causing a fire.

DO NOT touch hot surfaces and avoid hot exhaust gases.

Allow equipment to cool before touching.

Keep at least 5 ft. (152 cm) clearance on all sides of generator including overhead.

Code of Federal Regulation (CFR) Title 36 Parks, Forests, and Public Property require equipment powered by an internal combustion engine to have a spark arrester, maintained in effective working order, complying to USDA Forest service standard 5100-1C or later revision. In the State of California a spark arrester is required under section 4442 of the California Public resources code. Other states may have similar laws.

WARNING

Unintentional sparking can result in fire or electric shock.

WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR

Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug.

WHEN TESTING FOR ENGINE SPARK

Use approved spark plug tester.

DO NOT check for spark with spark plug removed.

CAUTION

Excessively high operating speeds increase risk of injury and damage to generator.

Excessively low speeds impose a heavy load.

DO NOT tamper with governed speed. Generator supplies correct rated frequency and voltage when running at governed speed.

DO NOT modify generator in any way.

CAUTION

Exceeding generators wattage/amperage capacity can damage generator and/or electrical devices connected to it.

See “Don’t Overload Generator”.

Start generator and let engine stabilize before connecting electrical loads.

Connect electrical loads in OFF position, then turn ON for operation.

Turn electrical loads OFF and disconnect from generator before stopping generator.

CAUTION

Improper treatment of generator can damage it and shorten its life.

Use generator only for intended uses.

If you have questions about intended use, ask dealer or call 1-800-743-4115.

Operate generator only on level surfaces.

DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.

DO NOT insert any objects through cooling slots.

If connected devices overheat, turn them off and disconnect them from generator.

Shut off generator if:

-electrical output is lost;

-equipment sparks, smokes, or emits flames; -unit vibrates excessively.

4

Image 4 Contents
Operator’s Manual Manual del Operario Starting WattsCall Generator Helpline Llame Línea Directa del Generador Safety Rules Table of ContentsEquipment Description When Adding or Draining Fuel When Starting EquipmentWhen Operating Equipment When Transporting or Repairing EquipmentWhen Adjusting or Making Repairs to Your Generator When Testing for Engine SparkKnow Your Generator Assembly Check Battery / Attach Negative Battery WireTo install Electric StartWhen Adding Fuel Before Starting the EngineAdd Engine Oil Add FuelUsing the Generator Connecting to a Building’s Electrical SystemSystem Ground Generator LocationOperating Generator Starting the EngineConnecting Electrical Loads ReceptaclesStopping the Engine Low Oil Pressure Shutdown System120/240 Volt AC, 30 Amp, Locking Receptacle Ground Fault ProtectionVolt AC, 15 Amp, Gfci Duplex Receptacles Testing the Gfci HOW to USE the Battery ChargerGenerator Adapter Cord SET Creating a Temporary Cold Weather Shelter Cold Weather OperationCreating a Permanent Cold Weather Shelter Power Management Dont Overload GeneratorCapacity ExampleProduct Specifications Generator SpecificationsEngine Specifications Engine Technical InformationGenerator Cleaning Generator MaintenanceGeneral Recommendations Engine Maintenance Battery MaintenanceFuel Valve Maintenance OilService Air Cleaner To clean or replace air cleaner componentsAdding Engine Oil Changing Engine Oil and Oil FilterClean Spark Arrester Screen Clean/Replace Spark PlugClean and inspect the spark arrester as follows Service Adjustments Checking/Adjusting Valve ClearanceCarburetor Adjustments To adjust valve clearanceTighten Jam Nut to 175 inch-pounds 19.7 N-m Storage Long Term Storage InstructionsProtect Fuel System GeneratorTroubleshooting Page Your Warranty Rights and Obligations Emissions Control Warranty Statement Emission Warranty Parts List Warranty is not Transferable This Warranty Shall not Apply to the FollowingLimited Warranty Tabla DE Contenidos Descripción DEL EquipoReglas DE Seguridad AdvertenciaCuando Añada Combustible O Vacíe EL Depósito Cuando Ponga EN Funcionamiento EL EquipoCuando Opere EL Equipo Cuando Transporte O Repare EL EquipoCuando Ajuste O Haga Reparaciones a SU Generador PrecauciónCuando Pruebe LA Bujía DEL Motor Tomacorriente Gfci Dobles de 120 Voltios AC, 15 Amp Conozca SU GeneradorTomacorriente con Dispositivo de Seguridad de Montaje Arranque EléctricoDesembalaje del Generador Para instalarAntes DE Darle Arranque AL Motor Agregar Aceite al MotorAgregue Combustible Cuando Añada CombustibleUSO DEL Generador Tierra del SistemaConexión al Sistema Eléctrico de un Edificio Ubicación del GeneradorOperando EL Generador Encienda el MotorSistema DE Parada POR Baja Presion DEL Aceite ReceptáculosConexion De Cargas Electricas Parado Del MotorVolt AC, 15 Amperios, Gfci Receptáculo Dobles 120/240 Voltios AC, 30 Amp, Receptáculo de SeguridadProtección Contra Fallos de Conexión a Tierra Cargador DE Batería Juego DE Cables DEL Adaptador DEL GeneradorComprobación del Gfci Operación Durante UN Clima Frío Figura 32 Clima Frío Estructura de ProtecciónNo Sobrecargue Generador CapacidadControl de la Energía EjemploInformación Técnica Sobre EL Motor Especificaciones DEL ProductoPeríodo de Cumplimiento del Motor Especificaciones del GeneradorMantenimiento DEL Generador Recomendaciones GeneralesLimpieza del Generador Mantenimiento DEL Motor Advertencia Mantenimiento de la BateríaMantenimiento de la Válvula de Combustible AceiteProporcione Servicio al Depurador de Aire Adición de Aceite del MotorCambio de Aceite del Motor y Filtro de Aceite Para limpiar o sustituir el filtro de aire componentesLimpie la Pantalla Apagachispas Limpie/Reemplace la BujíaLimpie e inspeccione el apagachispas de la siguiente manera Revisiones Y Ajustes Velocidad del MotorAjustes del Carburador Ajuste de la Separación de las VálvulasAlmacenamiento Almacenamiento Para Periodos ProlongadosProteja el Sistema de Combustible GeneradorProblemo Causa Accion Diagnositicos DE AveríasDerechos Y Obligaciones DE LA Garantía Garantía DE Control DE Emisiones EGR Notas Generac Power SYSTEMS, INC Plan DE GarantíaAplicaciones DE CONSUMO/COMERCIALES/INDUSTRIALES Esta Garantía no SE Aplicará EN LOS Siguientes CasosUso del consumidor Uso comercial