Thermal Solution
C ΨSA = ΨCA – ΨCS = 3.23 – 0.35 = 2.88°---
W
If the local ambient temperature is relaxed to 45° C, the same calculation can be carried out to determine the new
ΨCA = | TC – TLA |
| 105 – 45 | C |
= | = |
It is evident from the above calculations that a reduction in the local ambient temperature has a significant effect on the
Table 4 summarizes the thermal budget required to adequately cool the Intel® 6321ESB I/O Controller Hub in one configuration using a TDP of 12.4 W. Further calculations would need to be performed for different TDPs. Since the results are based on air data at sea level, a correction factor would be required to estimate the thermal performance at other altitudes.
Table 4. Required Heat Sink Thermal Performance (ΨCA)
Device | ΨCA (º C/W) at TLA = 45º C | ΨCA (º C/W) at TLA = 65º C | |
|
|
| |
Intel® 6321ESB I/O Controller | 4.84 | 3.23 | |
Hub @ 12.4 W | |||
|
| ||
|
|
|
Intel® 631xESB/632xESB I/O Controller Hub for Embedded Applications