Intel 632xESB Packaging Technology, Intel 6321ESB I/O Controller Hub Package Dimensions Top View

Page 9

Packaging Technology—Intel®6321ESB ICH

2.0Packaging Technology

The Intel® 6321ESB I/O Controller Hub component uses a 40 mm x 40 mm, 10-layer FC-BGA3 package (see Figure 2 and Figure 3).

Figure 2. Intel® 6321ESB I/O Controller Hub Package Dimensions (Top View)

 

 

 

Die

 

Handling

 

 

Keepout

 

Exclusion

19.49mm.

 

Area

 

Area

 

 

 

 

10.78mm.

 

6.17mm.

 

 

 

 

 

 

20.19mm. 13.99mm.

ESB2

26.0mm.

30.0mm.

40.0mm.

Die

 

 

 

 

3.10mm.

 

 

 

 

 

26.0mm.

 

 

 

 

30.0mm.

 

 

 

 

40.0mm.

 

 

 

Figure 3. Intel® 6321ESB I/O Controller Hub Package Dimensions (Side View)

Substrate

Decoup

 

 

 

2.535 ± 0.123 mm

 

Die

 

Cap

 

 

 

0.84 ± 0.05 mm

 

2.100 ± 0.121 mm

0.7 mm Max

0.20 See note 4.

 

 

 

 

 

0.20 –C–

0.435 ± 0.025 mm

 

 

Seating Plane

 

 

 

 

See note 1.

See note 3

 

 

 

Notes:

 

 

 

 

1.Primary datum -C- and seating plan are defined by the spherical crowns of the solder balls (shown before motherboard attach)

2.All dimensions and tolerances conform to ANSI Y14.5M-1994

3.BGA has a pre-SMT height of 0.5mm and post-SMT height of 0.41-0.46mm

4.Shown before motherboard attach; FCBGA has a convex (dome shaped) orientation before reflow and is expected to have a slightly concave (bowl shaped) orientation after reflow

Intel® 631xESB/632xESB I/O Controller Hub for Embedded Applications

February 2007TMDG 9

Image 9
Contents February Thermal and Mechanical Design GuidelinesPage Contents Tables Revision HistoryDate Revision Description 001 Initial public releaseDesign Flow IntroductionThermal Design Process Reference Documents Definition of TermsDefinition of Terms Term DefinitionTitle Location Referenced DocumentsPackaging Technology Intel 6321ESB I/O Controller Hub Package Dimensions Top ViewIntel 6321ESB ICH-Packaging Technology Thermal Design Power TDP Thermal SpecificationsDie Case Temperature Intel 6321ESB I/O Controller Hub Thermal SpecificationsThermal Simulation Characterizing the Thermal Solution Requirement Thermal Solution RequirementsExample 1. Calculating the Required Thermal Performance Processor Thermal Characterization Parameter RelationshipsRequired Heat Sink Thermal Performance ΨCA Device CA º C/W at T LA = 45º C CA º C/W at T LA = 65º CHub @ 12.4 W Die Case Temperature Measurements Thermal MetrologyZero Degree Angle Attach Methodology Thermal Solution Decision Flowchart Thermocouple Wire Die Substrate Cement + Thermocouple Bead Reference Thermal Solution Operating EnvironmentHeatsink Performance Mechanical Design Envelope Board-Level Components Keepout Dimensions Torsional Clip Heatsink Thermal Solution Assembly Torsional Clip Heatsink Board Component Keepout Heatsink OrientationThermal Interface Material Mechanical Interface MaterialClip Retention Anchors Heatsink ClipThermal Resistance C × in 2/W Pressure on IHSpsi End of Line End of Life§ § Reliability GuidelinesReliability Guidelines Test Requirement Pass/Fail CriteriaTorsional Clip Heatsink Thermal Solution Appendix a Thermal Solution Component SuppliersAppendix B Mechanical Drawings Mechanical Drawing ListDrawing Description Torsional Clip Heatsink Assembly Drawing Torsional Clip Heatsink Drawing Heat Sink Foam Gasket Drawing Torsional Clip Drawing