KODAK 1200i
c. Intermediate Reservoir:
-Intermediate reservoir located below ink bottle
-Provides consistent ink supply pressure (50 ml capacity)
-Replace ink
-Optical sensor monitors reservoir ink levels [ink level LOW warning sensor (<30ml;
d. Ink Supply Dampers and Septum Valve System:
-Ink flows through damper into a septum assembly (spring actuated ball valve to shutoff ink when cartridges are removed) Note: ink is filtered at the cartridge only.
e. Carriage Assembly:
-Robust carriage bushing design; thick bushings with 2 shims for better dimensional stability. Bushings are secured by bushing retainers.
-Bushings are grooved to minimize the effect of dirt and debris.
-Cartridge doors secure and bias print heads into proper position.
-
f. Cartridge / Printhead:
-Increased productivity with 640 nozzle print heads.
-Clean hands shipping and installation.
-Foam filled, eliminate tubing and needles.
-Ink filter.
-700 ml warranty; 2800 ml shutoff.
-1400 ml average print head life.
Technical Training Guide | 6 |