![](/images/new-backgrounds/1196250/19625085x1.webp)
KODAK 1200i WIDE-FORMAT PRINTING SYSTEM
2.For visible ink starvation (resembling large horizontal areas of ink dropout; no error condition displayed on control panel) first verify ink system flow and pressure are adequate (no bubbles greater than 1 cm in size within ink tubing should be visible) and check general cartridge health (via color test & prime pattern). Perform ‘System Prime’ (must have firmware version 2.1.0 loaded and the new service station must be installed), select:
UTILITY MENU – PRIME MENU – SERVICE STATION MENU – SYSTEM PRIME. Activation of the System Prime will fully recharge the entire ink system in ~60 seconds (also assumes factory set service station height is correct and the service station shim is installed properly) and helps correct ‘MAX INK TEMP errors’ and general cartridge ink depletion problems 90% of the time.
Technical Training Guide | 43 |