d) AC Isolation Transformers

-AC isolation transformers are common devices in electronic repair shops. Technicians use them to isolate the power on their repair benches from physical grounds in the repair shop (pipes, radiators, etc.) This is primarily for safety reasons. The same isolation transformers can be used to electrically isolate the printer from the AC power provided and thus break any ground loops. AC isolation transformers are typically placed in series between the power cord and printer.

-This is a costly solution and the benefits may

not be significant since the ground line will continue to float at the printer side. These devices are not suggested.

F. Related Print Symptoms

If data shift is observed at image edges combined with an image shift then this problem is typically a dirty encoder strip or dirty encoder sensor. Please refer to Technical Bulletin 5 for proper cleaning procedures.

DISCLAIMER:

This document has been provided as an aid to assist the installer/technician/authorized service provider, or electrician in solving a very specific issue regarding grounding related problems on the Kodak 1200i printer as detailed above. This document is not intended to assist with other electrical or equipment issues, nor does it supersede any regional electrical code regulations or ordinances. For grounding related problems on the Kodak 1200i, Encad Inc. encourages technicians or authorized service providers to suggest for the customer to consult a regionally certified electrician for advice/assistance, as needed, on a case by case basis. Encad Inc. is not responsible for any problems that arise or for any associated costs, in any way or manner, based on the information provided herein.

Technical Training Guide

74

Image 74
Contents Technical Training Guide Operational Space Requirements Presite Inspection pre-installationInstallation Requirements Power Requirements Connectivity RequirementsPrinter Features Intelligent Mask Technology IMTRapid Dryer Technology Ink System Ink ReservoirInk Supply Dampers and Septum Valve System Carriage AssemblyIntermediate Reservoir Cartridge / PrintheadService Station Auto Clean UnitPrint Speeds Power SupplyMedia Handling System Shipping Brackets Removal Printer Installation Quick StepsMedia System Installation 1 electrical connection Crossbar Installation Raise Printer Voltage Configuration for dryer systemReservoir Installation Cartridge Installation Ink Line FillingActivate ‘Prime All’ Test Pattern Printer Calibrations Example Assignments Example Assignments Color Cal Vertical. Select Utility Menu Best Quality ModePrint Pass Modes 2, 3, 4, 6, 8, 10, 12 Networking Peer-to-peer Windows 2000/XP example Kodak 1200i WIDE-FORMAT Printing System Load Windows Driver Kodak 1200i WIDE-FORMAT Printing System Configuration Double-check example only RIPPrint Mode & Dryer Guidelines Qi DyeQi Pigment Kodak Media Lamination Reference for Kodak 1200i Printer Lamination GuidelinesQi Pigment Printer Operation Tips Media Load and Verification‘Perfect’ Media Load Dryer ModesEdge Band mode Humidity ControlSoftware Control Tips Typical Server Installation one per subnetClient Installation one per workstation Printer Maintenance When a Print Head is ReplacedService Perform the followingRoutine Maintenance Kodak 1200i WIDE-FORMAT Printing System Clean the following items as required Cleaning Procedure Cleaning Procedure Replace the following item as required Preventive Maintenance Technical Bulletin Bulletin Reference ListKodak Error Message Codes Cartridge Error Messages/Cartridge FailuresType 3 Internal cartridge errors Kodak 1200i WIDE-FORMAT Printing System Kodak 1200i WIDE-FORMAT Printing System Black XXXmL If you then press the F1 key on the display you should seeAPC UNAVAILABLE, Abort JOB? PEN Error JOB Paused Color Pen Error Invalid Pen IDColor Pen Error Ink Warranty Mismatch Bottle Error JOB Paused Color INK Bottle Error = CodeColor Bottle Error Code # # ranges from 2 to Color Warning INK Reservoir LOW Kodak 1200i WIDE-FORMAT Printing System Dryer Sensor Fault Dryer System Fault Dryer OFFDryer WARMING-UP. Print ANYWAY? Dryer Temp TOO High Dryer OFFMiscellaneous Error Messages Internal Shutdown Carriage Axis FailureKodak 1200i WIDE-FORMAT Printing System JOB Pause E.O.M. Detected JOB Pause OUT of PaperPaper not Loaded Empty Waste Bottle NOWWaste Bottle Missing Mainboard ID ErrorMbid Error Invalid OEM ID PEN Error Waiting for Cartridge AccessCarriage Fpga Error Bottle ErrorKodak 1200i WIDE-FORMAT Printing System MAX INK TEMP. Advanced Analysis Bubbles Observed in Ink Delivery LinesMax Ink Temp. Errors Kodak 1200i WIDE-FORMAT Printing System Utility Menu Prime Menu Service Station Menu System Prime Printer Grounding/Static Control Data ShiftKodak 1200i WIDE-FORMAT Printing System Proper Power Cord & Grounding Intermittent Banding/Improper PrintAir Plenum Grounding HumidifiersAnt-Static Mats Testing AC level on printer chassis Rear Static Strip Condition & GroundingVerify Proper Receptacle Configuration Testing Receptacle Neutral-to-Ground VoltagePower/Voltage Testers Common Mistakes by Technicians/Customers Secondary GroundingProng to 2-Prong Adapters Related Print Symptoms AC Isolation Transformers
Related manuals
Manual 7 pages 43.35 Kb