Black Box KV0416A-R2, KV1424A-R2 manual Radio Frequency Energy, European EMC directive 89/336/EEC

Page 107

Radio Frequency Energy

A Category 5 (or better) twisted pair cable must be used to connect the units in order to maintain compliance with radio frequency energy emission regulations and ensure a suitably high level of immunity to electromagnetic disturbances.

All other interface cables used with this equipment must be shielded in order to maintain compliance with radio frequency energy emission regulations and ensure a suitably high level of immunity to electromagnetic disturbances.

European EMC directive 89/336/EEC

This equipment has been tested and found to comply with the limits for a class A computing device in accordance with the specifications in the European standard EN55022. These limits are designed to provide reasonable protection against harmful interference. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio or television reception. However, there is no guarantee that harmful interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment on and off, the user is encouraged to correct the interference with one or more of the following measures: (a) Reorient or relocate the receiving antenna. (b) Increase the separation between the equipment and the receiver. (c) Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. (d) Consult the supplier or an experienced radio/TV technician for help.

FCC Compliance Statement (United States)

This equipment generates, uses and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication.

It has been tested and found to comply with the limits for a class A computing device in accordance with the specifications in Subpart J of part 15 of FCC rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area may cause interference, in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference. Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment.

Canadian Department of Communications RFI statement

This equipment does not exceed the class A limits for radio noise emissions from digital apparatus set out in the radio interference regulations of the Canadian Department of Communications.

Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le règlement sur le brouillage radioélectriques publié par le ministère des Communications du Canada.

®

   



106

Image 107 Black Box KV0416A-R2 Radio Frequency Energy, European EMC directive 89/336/EEC, FCC Compliance Statement United States
Contents ServSwitch CX Contents Further information Index Introduction Front panel buttons ServSwitch CX features front and rearWhat’s in the box What you may additionally need ServSwitch CX ServSwitch CX with IPConnections MountingRack brackets Connections To connect the local user port Local userTo connect a remote user Remote user via CX Remote extenderCable lengths for remote user locations To connect the Global user IP network port Global user IP network portTo connect a server system Server system via SAMTo connect a modem or Isdn adapter Modem/ISDN portTo connect the power supply Power in connectionTo connect and address the switch boxes Power control portSee also Cascading multiple unitsHow cascade connections operate 43 41 Addressing servers in a cascadeTo connect units in cascade Connecting ServSwitch CX units in cascadeNumbering diagram Tips for successful cascadingTo test a specific link Using cascaded serversTesting specific links to cascaded servers Multiple video head connections Slave ServSwitch CXOverall initial configuration Hotkeys Configuration menusTo access the configuration menu local and remote users To access the configuration menu global usersTo set an Admin password General security and configuration stepsConfiguration menus layout To enable general securityTo create/edit user accounts Admin userAccess to all servers Press Access to no servers Press Registering users edit user listTo create/edit server entries Tips when creating/editing server entriesRegistering servers edit computer list Video compensation See Remote user skew adjustment for detailsVertical edges of images Server video compensationTo apply server video compensation If the image controls cannot provide a crisp image Remote user video compensationTo display a suitable high contrast image To apply remote user video compensationCreating a skew test pattern Remote user skew adjustmentTo use skew adjustment Using the supplied skew patternNum Lock for Red, Caps Lock for Green To define an autoscan list To select an autoscan modeAutoscanning To select an autoscan periodPreparations for configuration save/load Saving and restoring configuration settingsConfiguration screens What to do if the Admin password has been forgottenTo reset ServSwitch CX models To reset the ServSwitch CX with IP modelsRecognising an IntelliMouse-style mouse Which restore setting do I use?To restore mouse operation when hot plugging Hot plugging and mouse restorationTo configure IP-specific settings Initial IP configurationTo use the initial IP-configuration sequence User Accounts IP configuration by global userTo configure IP details from a global user location Viewer encryption settings Encryption settingsServSwitch CX with IP encryption settings Positioning ServSwitch CX with IP in the network Networking issuesAddressing Placing ServSwitch CX with IP behind a router or firewallPort settings DNS addressing To discover a DHCP-allocated IP addressPorts Placing ServSwitch CX with IP alongside the firewallBy configuration page via viewer Ensuring sufficient securityTo control two or more ports simultaneously Power switching configurationPower control sequences To configure the power sequences for each host serverKvmadmin -setusers users.csv Kvmadmin utilityKvmadmin command ip address parameters Kvmadmin -getconfig kvm1.cfgTo use the KVM Firmware Uploader utility Performing upgradesUpgrading ServSwitch CX models and SAMs Items required to use the upgrade utilityCommence the upgrade Select the items to be upgradedSelect the upgrade file to be used Where Vxxx is the upgrade file version numberPerform upgrade button Upgrading ServSwitch CX with IP modelsTo upgrade ServSwitch CX with IP models User button and numeric indicator ServSwitch CX modelsServSwitch CX with IP models Computer button and numeric indicatorSelecting a server Local and remote user accessTo gain access as a local or remote user To select a server using the front panel controlsKeep Pressed down until all other Numbers have been entered To select a server using hotkeysStandard hotkeys To select a server using mouse buttons Advanced method To select a server using the on-screen menuTo select a server using mouse buttons Confirmation box Logging in and outSelecting cascaded servers Routing status To change banner colours or disable the bannerTo use the Routing status feature Reminder bannerUser preferences and functions Power switching via configuration menuTo switch a server on or off Global user access To download the VNC viewer Global user access via VNC viewerTo access via the VNC viewer To access via your web browser Global user access via web browserMenu bar Using the viewer windowWhen using the viewer window To select a host ConfigureMouse pointers Re-synchronise mouse Access mode shared/privatePower switching via viewer Auto calibrateResync Mouse Single Mouse ModeControls Mouse ControlKeyboard Control Info KVM switch menuWhen entering codes Video SettingsHost system information Using automatic configurationsIncreased by 50% when a slow link is detected Setting the Threshold manuallyTo enter a port number in a Web browser Access via dial up modem or Isdn linkIf you need to enter a port number To initiate a dial up linkLinux Viewer encryption settingsSupported web browsers WindowsTechhelp@blackbox.co.uk TroubleshootingWhen logging on using VNC viewer, I cannot enter a username Getting assistanceConfigure IP port Appendix 1 Configuration menusTo access the configuration menus Functions Reminder Colour User PreferencesOSD Colour Reminder BannerScreen Saver Mouse SwitchingAutoscan Mode Global PreferencesMouse Type User TimeoutOSD Dwell Time RS232 Mouse TypeExclusive Use Setup OptionsKeypads Controls LanguageAutomatic Logout DDC Options Advanced OptionsUnit Configuration Configure IP portNetwork Configuration Reset Configuration Modem ConfigurationTo clear IP access control Clearing IP access controlWhat is IP access control? To access the remote configuration pages Appendix 2 Configuration pages via viewerUser accounts Firmware Version Unit configurationAdmin Password Hardware VersionAdvanced unit configuration Time & date configuration IP Network Mask Network configurationIP Access Control MAC addressTo edit/remove access control entries Setting IP access controlTo define a new IP access control entry To reorder access control entriesModem port Serial port configurationPower control port To create a new host entry Host configurationErase Host Configuration Add entry for unrecognised hostExamples Port/host addressing using Port DirectPort Direct For further details To get here Logging and statusTo copy and paste the log Syslog Server IP AddressPreferred encoding Appendix 3 VNC viewer connection optionsColour/Encoding Auto selectCustomise Enable all inputsDisable all inputs view-only mode InputsMisc ScalingLoad / Save Defaults ReloadDefaults Save IdentitiesAppendix 4 VNC viewer window options Security Appendix 5 Browser viewer optionsEncoding and colour level Want to know more? Appendix 6 Addresses, masks and portsIP addresses Net masksNet masks the binary explanation 154Address ranges Calculating the mask for IP access controlSingle locations All locationsPorts Security issues with portsRS232 serial flash upgrade cable Appendix 7 Cable and connector specificationsPower switch to power switch daisy chain cable Multi-head synchronisation cable Creating macro sequences Appendix 8 Hotkey sequence codesPermissible key presses Appendix 9 Supported video modes General Public License Linux Safety informationEnd user licence agreement Canadian Department of Communications RFI statement Radio Frequency EnergyEuropean EMC directive 89/336/EEC FCC Compliance Statement United StatesCertification notice for equipment used in Canada FCC requirements for telephone-line equipmentInstrucciones de seguridad Normas Oficiales Mexicanas NOM electrical safety statement109 Index 111 112 Country Web Site/Email Phone Fax BlackBox subsidiary contact details