Configure IP port

Unit Configuration

®

Available only on ServSwitch CX with IP models, the IP port configuration menu allows you to determine settings that relate directly to the global (IP) user aspects of the unit:

Unit Configuration

 

IP admin password, encryption

 

settings, etc.

Network Configuration

SERVSWITCH CX

Configuration

Unit Configuration

Network Configuration

Modem Configuration

Reset Configuration

Back

This page provides access to a selection of both basic and fundamental settings for the ServSwitch CX with IP.

Keyboard

Use the arrow buttons to match the keyboard layout expected by the host system.

SERVSWITCH CX

Unit Config

 

Hardware

Rev 1

Firmware

1.0b7

Keyboard

UK

Admin Pwd

 

Unit Name

AV CATx

Time

11 : 14 : 44

Date

27 Apr 2006

Encryption

Prefer Off



 

IP address, net mask, VNC port,

 

etc.

Modem Configuration

 

Baud rate, initialisation string,

 

etc.

Reset Configuration

 

Completely resets the IP portion

 

of the ServSwitch CX with IP unit.

Enter-Select

Esc-Exit

-Up -Down

 

Admin Pwd

 

 

Enter the password that will be used

Enter-Select

Esc-Exit

to gain administrator access to the

-Up -Down

Space-Toggle

ServSwitch CX with IP. There can only

 

 

be one admin user and only that user

 

 

is given access to the configuration menus. The admin password background will be red until a reasonably secure password has been entered, although this is only advisory as any password or no password may be entered.

Unit Name



To get here

1From a local or remote (not accessible from a global keyboard), log on as the ‘admin’ user.

2Press (hotkeys can change).

3Press to select ‘More menus’.

4Select ‘Functions’.

5Select ‘Configure IP port’.

The name entered here will be displayed on the local menus and the remote VNC/browser windows.

Time and Date

Use the left and right arrow keys to select the correct time and date. The time entry uses the 24 hour clock notation. The internal real time clock will continue to run for roughly one week without power to the unit, after that it will be lost and require resetting. Use the up and down arrow keys to move between each of the sections within the time and date entries.

Encryption

Three options are available: Always on, prefer off, prefer on. The one to choose depends on the specific details of your installation - see Encryption settings for details. The use of encryption imposes a slight performance overhead of roughly 10% but is highly secure against third party intrusion.

 



75

Image 76
Contents ServSwitch CX Contents Further information Index Introduction ServSwitch CX features front and rear Front panel buttonsServSwitch CX ServSwitch CX with IP What’s in the box What you may additionally needRack brackets MountingConnections Connections Local user To connect the local user portCable lengths for remote user locations Remote user via CX Remote extenderTo connect a remote user Global user IP network port To connect the Global user IP network portServer system via SAM To connect a server systemModem/ISDN port To connect a modem or Isdn adapterPower in connection To connect the power supplyPower control port To connect and address the switch boxesCascading multiple units See alsoHow cascade connections operate Addressing servers in a cascade 43 41Connecting ServSwitch CX units in cascade Numbering diagramTips for successful cascading To connect units in cascadeTesting specific links to cascaded servers Using cascaded serversTo test a specific link Slave ServSwitch CX Multiple video head connectionsOverall initial configuration Configuration menus To access the configuration menu local and remote usersTo access the configuration menu global users HotkeysGeneral security and configuration steps Configuration menus layoutTo enable general security To set an Admin passwordAdmin user Access to all servers Press Access to no servers PressRegistering users edit user list To create/edit user accountsRegistering servers edit computer list Tips when creating/editing server entriesTo create/edit server entries See Remote user skew adjustment for details Video compensationTo apply server video compensation Server video compensationVertical edges of images Remote user video compensation To display a suitable high contrast imageTo apply remote user video compensation If the image controls cannot provide a crisp imageRemote user skew adjustment To use skew adjustmentUsing the supplied skew pattern Creating a skew test patternNum Lock for Red, Caps Lock for Green To select an autoscan mode AutoscanningTo select an autoscan period To define an autoscan listSaving and restoring configuration settings Preparations for configuration save/loadWhat to do if the Admin password has been forgotten To reset ServSwitch CX modelsTo reset the ServSwitch CX with IP models Configuration screensWhich restore setting do I use? To restore mouse operation when hot pluggingHot plugging and mouse restoration Recognising an IntelliMouse-style mouseTo use the initial IP-configuration sequence Initial IP configurationTo configure IP-specific settings To configure IP details from a global user location IP configuration by global userUser Accounts ServSwitch CX with IP encryption settings Encryption settingsViewer encryption settings Networking issues Positioning ServSwitch CX with IP in the networkPort settings Placing ServSwitch CX with IP behind a router or firewallAddressing To discover a DHCP-allocated IP address DNS addressingPlacing ServSwitch CX with IP alongside the firewall By configuration page via viewerEnsuring sufficient security PortsPower switching configuration Power control sequencesTo configure the power sequences for each host server To control two or more ports simultaneouslyKvmadmin utility Kvmadmin command ip address parametersKvmadmin -getconfig kvm1.cfg Kvmadmin -setusers users.csvPerforming upgrades Upgrading ServSwitch CX models and SAMsItems required to use the upgrade utility To use the KVM Firmware Uploader utilitySelect the items to be upgraded Select the upgrade file to be usedWhere Vxxx is the upgrade file version number Commence the upgradeTo upgrade ServSwitch CX with IP models Upgrading ServSwitch CX with IP modelsPerform upgrade button ServSwitch CX models ServSwitch CX with IP modelsComputer button and numeric indicator User button and numeric indicatorLocal and remote user access To gain access as a local or remote userTo select a server using the front panel controls Selecting a serverStandard hotkeys To select a server using hotkeysKeep Pressed down until all other Numbers have been entered To select a server using mouse buttons To select a server using the on-screen menuTo select a server using mouse buttons Advanced method Selecting cascaded servers Logging in and outConfirmation box To change banner colours or disable the banner To use the Routing status featureReminder banner Routing statusTo switch a server on or off Power switching via configuration menuUser preferences and functions Global user access To access via the VNC viewer Global user access via VNC viewerTo download the VNC viewer Global user access via web browser To access via your web browserWhen using the viewer window Using the viewer windowMenu bar Mouse pointers ConfigureTo select a host Access mode shared/private Power switching via viewerAuto calibrate Re-synchronise mouseSingle Mouse Mode ControlsMouse Control Resync MouseKVM switch menu When entering codesVideo Settings Keyboard Control InfoUsing automatic configurations Increased by 50% when a slow link is detectedSetting the Threshold manually Host system informationAccess via dial up modem or Isdn link If you need to enter a port numberTo initiate a dial up link To enter a port number in a Web browserViewer encryption settings Supported web browsersWindows LinuxTroubleshooting When logging on using VNC viewer, I cannot enter a usernameGetting assistance Techhelp@blackbox.co.ukTo access the configuration menus Appendix 1 Configuration menusConfigure IP port Functions User Preferences OSD ColourReminder Banner Reminder ColourMouse Switching Autoscan ModeGlobal Preferences Screen SaverUser Timeout OSD Dwell TimeRS232 Mouse Type Mouse TypeSetup Options Keypads ControlsLanguage Exclusive UseAutomatic Logout Advanced Options DDC OptionsConfigure IP port Unit ConfigurationNetwork Configuration Modem Configuration Reset ConfigurationWhat is IP access control? Clearing IP access controlTo clear IP access control Appendix 2 Configuration pages via viewer To access the remote configuration pagesUser accounts Unit configuration Admin PasswordHardware Version Firmware VersionAdvanced unit configuration Time & date configuration Network configuration IP Access ControlMAC address IP Network MaskSetting IP access control To define a new IP access control entryTo reorder access control entries To edit/remove access control entriesPower control port Serial port configurationModem port Host configuration Erase Host ConfigurationAdd entry for unrecognised host To create a new host entryPort Direct Port/host addressing using Port DirectExamples Logging and status To copy and paste the logSyslog Server IP Address For further details To get hereAppendix 3 VNC viewer connection options Colour/EncodingAuto select Preferred encodingEnable all inputs Disable all inputs view-only modeInputs CustomiseScaling MiscDefaults Reload Defaults SaveIdentities Load / SaveAppendix 4 VNC viewer window options Encoding and colour level Appendix 5 Browser viewer optionsSecurity Appendix 6 Addresses, masks and ports IP addressesNet masks Want to know more?154 Net masks the binary explanationCalculating the mask for IP access control Single locationsAll locations Address rangesSecurity issues with ports PortsPower switch to power switch daisy chain cable Appendix 7 Cable and connector specificationsRS232 serial flash upgrade cable Multi-head synchronisation cable Permissible key presses Appendix 8 Hotkey sequence codesCreating macro sequences Appendix 9 Supported video modes Safety information General Public License LinuxEnd user licence agreement Radio Frequency Energy European EMC directive 89/336/EECFCC Compliance Statement United States Canadian Department of Communications RFI statementFCC requirements for telephone-line equipment Certification notice for equipment used in CanadaNormas Oficiales Mexicanas NOM electrical safety statement Instrucciones de seguridad109 Index 111 112 BlackBox subsidiary contact details Country Web Site/Email Phone Fax