Black Box COMPACT T1 quick start LEDs, State Description

Page 35

Quick Start

Controller Cards

LEDs

The T1 Controller has a set of six LEDs you can use to troubleshoot your Compact T1. The table below describes each LED.

LED

State

Description

 

 

 

MAJOR

Off

No major alarms present

 

 

 

 

Red

Major alarm present

 

 

 

MINOR

Off

No minor alarms present

 

 

 

 

Yellow

Minor alarms present

 

 

 

LOCAL

Off

Remote mode (DIP switches disabled)

 

 

 

 

Green

Local mode (DIP switches enabled)

 

 

 

ACO

Off

Normal mode. No alarms are being

 

 

suppressed.

 

 

 

 

Yellow

Alarm cutoff active. One or more active

 

 

alarms suppressed.

 

 

 

T1-1 and

Off

Off line

T1-2

 

 

Green

Normal

 

 

 

 

 

Red

Loss of Signal (LOS) detected

 

 

 

 

Yellow

Bipolar Violation (BPV) detected

 

 

 

 

Flashing Green

Loopback active

 

 

 

 

Flashing Red

Loss of Frame (LOF) or Alarm Indication

 

 

Signal (AIS) detected

 

 

 

 

Flashing Yellow

Yellow alarm (Remote Alarm Indication)

 

 

detected.

 

 

 

Compact T1 - Release 6.1

31

Image 35
Contents Compact T1 Supporting Software Version Preface Safety InformationElectrostatic Discharge ESD Precautions Quick Start Unpacking and Inspection Installation EnvironmentAssembly of Compact T1 Wall Mounting To rack mount the Unit, follow the instructions below Rack Mounting Optional FeatureHeat Baffle Left Side View Thumbscrew Quick Start Power Cables Compliant InstallationFerrite Beads shipped with Adit chassis Service Card Cables that Require Additional Ferrite BeadsFerrite Beads Interface Connectors Chassis Connectors and ButtonsGround Terminals Chassis Ground Connector48V Battery Power ResetPower Connections AC PowerTo connect -48 VDC power Pin # Description Explanation External Alarm ConnectorPair Pin Location Function Color Code Pair Telco ConnectorsQuick Start Direction Description RS-232 Craft Port Female DB-9Ethernet RJ-45 T1 Connection Ports10Base-T Ethernet T1 RJ-48CLocal and Remote Management Option Command Line Interface CLISetting up a CLI connection Set the port settings to 9600 baud 8/N/1/No Flow ControlConfiguration Command Initial SetupSet Up Security Set Up a DS0/Channel Set Up a DS1/T1Set Up an Analog Port Set Up the Router IP or CMG Cards Establish a Static Channel Connection Set Up a Isdn BRI ServiceSet Up the OCU-DP Card Change the IP Address of the DS0 Management Channel Set Up a V.35 PortInstall Country Specific Ringer Tones Upgrade the Controller SoftwareUpgrade the Router IP or CMG Software T1 Controller Card Dip SwitchesSwitch Function Description Controller CardsState Description LEDs115 VAC/-48 VDC Power Supply Power SuppliesFXO Card Service CardsDIP Switch Settings FXS Intl card FXS CardOCU-DP Card Isdn BRI Card35/V.54 Card Quad T1 CardCRD CMG Router CardCOL IP Router Card