Black Box COMPACT T1 quick start Set Up the Router IP or CMG Cards

Page 29

Quick Start

Configuration

Set Up the Router (IP or CMG) Cards

See the Router (IP or CMG) Quick Start Guides for detailed information. The following is the basic setup, see the Router family User Manuals or Quick Start Guides for the following configuration setups:

λPPP Internet Connection and Public IP Address Routing

λFrame Relay Internet Connection and Public IP Address Routing

λInternet Connection using PPP, NAT/PAT and Firewall Filters

λInternet Connection using NAT and Static NAT Addresses

λPPP Internet Connection and Public IP Address Routing

λBack-to-Back with PPP

Command

set {ds0-addr} type data

connect {slot:port:trunk} {slot:port:channel}

set {router-addr} proxy

set {slot:port} up

telnet {router_card-addr}

Local and Remote Profile Setup reinitialize

Description

Confirm DS0 is set to type data. ds0-addr = {slot:port:channel} of DS0 Example: set a:1:1-24 type data

Cross-connect T1 to router card.

Example: connect a:1:1-24 6:1:1 (router in slot 6)

Disable/enable router proxy. router-addr = {slot:port} of router card. Example: set 6:1 proxy disable.

Set Router LAN as In-Service.

Example: set 6:1 up

Telnet to Router card.

router_card-addr = {slot} location of router card Example: telnet 6 (if earlier than 3.0 release {slot:port} must be used)

To enable any configuration changes, the card must be reinitialized.

Compact T1 - Release 6.1

25

Image 29
Contents Compact T1 Supporting Software Version Preface Safety InformationElectrostatic Discharge ESD Precautions Quick Start Unpacking and Inspection Installation EnvironmentAssembly of Compact T1 Wall Mounting To rack mount the Unit, follow the instructions below Rack Mounting Optional FeatureHeat Baffle Left Side View Thumbscrew Quick Start Power Cables Compliant InstallationFerrite Beads shipped with Adit chassis Service Card Cables that Require Additional Ferrite BeadsFerrite Beads Interface Connectors Chassis Connectors and ButtonsGround Terminals Chassis Ground ConnectorPower Connections Power ResetAC Power 48V BatteryTo connect -48 VDC power Pin # Description Explanation External Alarm ConnectorPair Pin Location Function Color Code Pair Telco ConnectorsQuick Start Direction Description RS-232 Craft Port Female DB-910Base-T Ethernet T1 Connection PortsT1 RJ-48C Ethernet RJ-45Setting up a CLI connection Command Line Interface CLISet the port settings to 9600 baud 8/N/1/No Flow Control Local and Remote Management OptionConfiguration Command Initial SetupSet Up Security Set Up a DS0/Channel Set Up a DS1/T1Set Up an Analog Port Set Up the Router IP or CMG Cards Establish a Static Channel Connection Set Up a Isdn BRI ServiceSet Up the OCU-DP Card Change the IP Address of the DS0 Management Channel Set Up a V.35 PortInstall Country Specific Ringer Tones Upgrade the Controller SoftwareUpgrade the Router IP or CMG Software Switch Function Description Dip SwitchesController Cards T1 Controller CardState Description LEDs115 VAC/-48 VDC Power Supply Power SuppliesFXO Card Service CardsDIP Switch Settings FXS Intl card FXS CardOCU-DP Card Isdn BRI Card35/V.54 Card Quad T1 CardCRD CMG Router CardCOL IP Router Card