Black Box COMPACT T1 quick start Service Cards, FXO Card, DIP Switch Settings

Page 37

Quick Start

Service Cards

Service Cards

FXO Card

DIP Switch Settings

The DIP switches on the FXO card control all eight channels. In order to apply different settings to channels on the same card, use the CLI.

Switch

Function

Description

Note

1-2

Signal

1 2

 

 

 

 

Type

 

 

 

0 0 = FXO Loop Start

 

 

 

1 0 = FXO Ground Start

 

 

 

0 1 = DPT (use with E&M setting

 

 

 

on T1)

 

 

 

 

 

1 1 = FXO Loop Start with

 

 

 

Calling Party Disconnect

 

 

 

 

 

 

 

3-6

Receive

3 4 5 6

 

 

These settings allow for

 

Gain/Loss

 

 

receive gain and losses of -9, -

 

0 0 0 0 =

0 dB

 

 

0 0 0 1

=

-9 dB

7, -6, -5, -4, -3, -2, 0, 2, 3, 4,

 

 

0 0 1 0

=

+2 dB

5, 6, and 7. +9 (1110 is not

 

 

0 1 0 0

=

+3 dB

available.

 

 

1 0 0 0

=

+4 dB

 

 

 

 

 

 

7-10

Transmit

7 8 9 10

 

These settings allow for

 

Gain/Loss

 

 

transmit gain and losses of -9,

 

0 0 0 0 =

0 dB

 

 

0 0 0 1

=

-9 dB

-7, -6, -5, -4, -3, -2, 0, 2, 3, 4,

 

 

0 0 1 0

=

+2 dB

5, 6, and 7. +9 (1110 is not

 

 

0 1 0 0

=

+3 dB

available.

 

 

1 0 0 0

=

+4 dB

 

 

 

 

 

 

 

LEDs

Each port on the FXO card has its own LED, as described in the table below

 

State

Loop Start

Ground Start Meaning

Dial Pulse Termination

 

 

Meaning

 

Meaning

 

 

 

 

 

 

Off

N/A

Idle (tip open)

Idle (loop open)

 

 

 

 

 

 

Green

Idle

Tip ground (incoming seizure)

Incoming seizure

 

 

 

 

 

 

Red

N/A

Ring ground (outgoing seizure)

Loop closure (outgoing seizure)

 

 

 

 

 

 

Yellow

Call in progress

Call in progress

Call in progress (reverse battery)

 

 

 

 

 

 

Flashing Green

Ringing

Ringing

N/A

 

 

 

 

 

Compact T1 - Release 6.1

33

Image 37
Contents Compact T1 Supporting Software Version Preface Safety InformationElectrostatic Discharge ESD Precautions Quick Start Unpacking and Inspection Installation EnvironmentAssembly of Compact T1 Wall Mounting To rack mount the Unit, follow the instructions below Rack Mounting Optional FeatureHeat Baffle Left Side View Thumbscrew Quick Start Power Cables Compliant InstallationFerrite Beads Service Card Cables that Require Additional Ferrite BeadsFerrite Beads shipped with Adit chassis Interface Connectors Chassis Connectors and ButtonsGround Terminals Chassis Ground ConnectorPower Connections Power ResetAC Power 48V BatteryTo connect -48 VDC power Pin # Description Explanation External Alarm ConnectorPair Pin Location Function Color Code Pair Telco ConnectorsQuick Start Direction Description RS-232 Craft Port Female DB-910Base-T Ethernet T1 Connection PortsT1 RJ-48C Ethernet RJ-45Setting up a CLI connection Command Line Interface CLISet the port settings to 9600 baud 8/N/1/No Flow Control Local and Remote Management OptionConfiguration Set Up Security Initial SetupCommand Set Up a DS0/Channel Set Up a DS1/T1Set Up an Analog Port Set Up the Router IP or CMG Cards Establish a Static Channel Connection Set Up a Isdn BRI ServiceSet Up the OCU-DP Card Change the IP Address of the DS0 Management Channel Set Up a V.35 PortUpgrade the Router IP or CMG Software Upgrade the Controller SoftwareInstall Country Specific Ringer Tones Switch Function Description Dip SwitchesController Cards T1 Controller CardState Description LEDs115 VAC/-48 VDC Power Supply Power SuppliesDIP Switch Settings Service CardsFXO Card FXS Intl card FXS CardOCU-DP Card Isdn BRI Card35/V.54 Card Quad T1 CardCRD CMG Router CardCOL IP Router Card