Xantrex Technology ENET-XFR3 manual Configuring for Ethernet or RS-232

Page 34

Installation and Configuration

Configuring for Ethernet or RS-232

This interface card can be configured for Ethernet communication, or for RS-232communication, but not both simultaneously. From the factory, the instrument will be configured for Ethernet communication. Therefore you should only need to follow these instructions if you are switching over to RS-232, or back to Ethernet. To switch between the two configurations, you must change internal jumpers on the interface card. See “Changing Internal Jumpers” on page 2–8. Also refer to Table 2-2and Figure 2-3 on page 2–6to locate the corresponding jumpers.

Table 2-5Jumper positions for Ethernet or RS-232

When you have finished changing the jumper positions, ensure that the

J3

1RS-2-232

Ethernet2-3

 

 

 

 

 

J4

1-2

2-3

 

 

 

 

 

J5

1-2

2-3

 

 

 

 

 

J6

1-2

2-3

 

Jumper

 

 

 

 

 

 

 

ba

d rate, flow control, and power-on state are configured properly for

yo

n w setup. These settings are also changed by adding or removing

jumpers, so it is best to perform this adjus m nt, if necessary, while the interface card is accessible. Refer to “Baud Rate Selection” on page 2–18, “Flow Control Selection” on page 2–19and “Remote/Local Mode Startu ” on page 2–20for more detailed information on how to reconfigure these settings.

Note: If you are switching the interface card back to Ethernet it is recommended to set the baud rate to 9600, turn flow control off, and have the unit power-on in remote mode (these are the default settings).

2–12

TM-XR9B-01XN

Image 34
Contents Operating Manual Page XFR 1.2kW and 2.8kW Ethernet/RS-232 Interface Option Date and Revision Scope PurposeAudience Organization Conventions Used Related InformationPage Important Safety Instructions Viii Contents Operation Advanced Ethernet Administration SpecificationsCalibration Xii Figures Xiv Tables Xvi Features DescriptionFeatures and Functions Interface FeaturesProgrammable Functions Ethernet FeaturesReadback Functions Page Configuration IntroductionFor RS-232 Initial Inspection ERR Front PanelSRQ FLT1Item Ethernet/RS-232 Interface PCB 2Ethernet/RS-232 Interface Jumper Selections XoffProcedure for 1.2kW XFR Changing Internal JumpersProcedure for 2.8kW XFR 1Step#DescriptionActionModeConfigure for Ethernet Basic Setup Procedure EthernetBasic Setup Procedure RS-232 1StepConfiguring for Ethernet or RS-232 EthernetEthernet Communications Ethernet ConnectionLocating the Power Supply on Your Network Configuring Ethernet Bridge Installing and Using RealPort1 BackgroundRS-232Communications RS-232 Connection6Jumper J2 Settings for Baud Rate Baud Rate SelectionFlow Control Selection 7Jumper J2 Flow Control SectionRemote/Local Mode Startup Remote/Local OperationRemote Mode Operation Local Mode Operation Remote Enable REN CommandXON/XOFF Power Supply SettingsLocal Lockout LLO Command RTS/CTSAdditional User Options and Settings OVP SelectionLowon TTL Shutdown PolarityHigh LOW OFF User Signals User Lines ConnectorUser Lines Signal Connector Circuit Block Diagram User Lines Cable Connection 7User Lines Cable with Ferrite BlockOperation RS-232Operation Command SyntaxManual Conventions Command Format and Parameters FormatFlo ting Point Number floa Order Command StringsCommand Terminators Iset 2.0A VsetCommand Summary DLY? AUXB?CMODE? ERR?IHI FAULT?Idata ILOAUXA? Command ReferenceCmode 1/ON Description AlsoRemote/Local Operation on Chapter Mask None = Unmask ALL ALL, None Command Voltage settings which are being held. See Hold command Accumulated Status, Status, and Fault Registers ASTS?ACF PONREM OPFError0 #ErrorNo ErrorsIdentificationExplanation Error CodesTroubleshooting Diagnostic LEDsEthernet Mode Troubleshooting Tips 10 Ethernet Mode TipsPossibleCauses RS-232Mode Troubleshooting Tips RS-232and/or Ethernet Mode Troubleshooting TipsPage Calibration Calibration Voltage Calibration Setup Voltage Mode CalibrationVoltage Program Calibration Procedure Voltage Readback Calibration Procedure Current Calibration Setup Current Mode CalibrationCurrent Program Calibration Procedure Current Readback Calibration Procedure Over Voltage Protection OVP Calibration Page Specifications 40-30 OVP600-2 40-70 600-4 Page Administration Changing the Root Password Resetting the Configuration from a Browser Resetting the Configuration to DefaultsIntroduction Viewing Port Statistics and Settings Copying the Configuration to and from a ServerViewing Network Statistics NET Interpreting LED InformationDIA Page Warranty and Product Information WarrantyDisclaimer ProductReturn Material Authorization Policy ExclusionsOut of Warranty Service Return ProcedureInformation About Your System Page Xantrex Technology Inc