Xantrex Technology ENET-XFR3 Idata, Ihi, Ilo, Irdat, Irhi, Irlo, Ovcal, Vdata, Vhi, Vlo, Vrdat

Page 58

Operation

Table 3-5Calibration Commands

CMODECommand

DescriptionPlaces the supply into calibration mode.

IDATA

Calculates the slope and intercept for current programming.

 

 

IHI

Sets the current output to the high calibration point.

 

 

ILO

Sets the current output to the low calibration point.

 

 

IRDAT

Calculates the slope and intercept for current readback.

 

 

IRHI

Sets the current output to the high readback point.

 

 

IRLO

Sets the current output to the low readback point.

 

 

OVCAL

Calibrates the over voltage protection (OVP).

 

 

VDATA

Calculates the slope and intercept for voltage programming.

 

 

VHI

Sets the voltage output to the high calibration point.

 

 

VLO

Sets the voltage output to the low calibration point.

 

 

VRDAT

Calculates the slope and intercept for voltage readback.

 

 

VRHI

Sets the voltage output to the high readback point.

 

 

VRLO

Sets the voltage output to the low readback point.

 

Table 3-6Status Commands

 

 

 

 

ASTS?Command

DescriptionAsks for the supply’s accumulated status register.

 

 

FAULT?

Asks for the supply’s fault register for the status preset operating

 

conditions.

 

 

MASK

Prevents the supply's previously unmasked operating conditions

 

from setting bits in the fault register.

 

 

STS?

Asks for the supply’s present status register.

 

 

UNMASK

Enables you to select those supply's operating conditions that you

 

are most interested in monitoring for fault occurrence.

 

 

UNMASK?

Asks for the supply's fault conditions which are currently enabled

 

(unmasked).

 

 

3–8

TM-XR9B-01XN

Image 58
Contents Operating Manual Page XFR 1.2kW and 2.8kW Ethernet/RS-232 Interface Option Date and Revision Scope PurposeAudience Organization Conventions Used Related InformationPage Important Safety Instructions Viii Contents Operation Advanced Ethernet Administration SpecificationsCalibration Xii Figures Xiv Tables Xvi Features DescriptionFeatures and Functions Interface FeaturesProgrammable Functions Ethernet FeaturesReadback Functions Page Configuration IntroductionFor RS-232 Initial Inspection ERR Front PanelSRQ FLT1Item Ethernet/RS-232 Interface PCB 2Ethernet/RS-232 Interface Jumper Selections XoffProcedure for 1.2kW XFR Changing Internal JumpersProcedure for 2.8kW XFR 1Step#DescriptionActionModeConfigure for Ethernet Basic Setup Procedure EthernetBasic Setup Procedure RS-232 1StepConfiguring for Ethernet or RS-232 EthernetEthernet Communications Ethernet ConnectionLocating the Power Supply on Your Network Configuring Ethernet Bridge Installing and Using RealPort1 BackgroundRS-232Communications RS-232 Connection6Jumper J2 Settings for Baud Rate Baud Rate SelectionFlow Control Selection 7Jumper J2 Flow Control SectionRemote/Local Mode Startup Remote/Local OperationRemote Mode Operation Local Mode Operation Remote Enable REN CommandXON/XOFF Power Supply SettingsLocal Lockout LLO Command RTS/CTSAdditional User Options and Settings OVP SelectionLowon TTL Shutdown PolarityHigh LOW OFF User Signals User Lines ConnectorUser Lines Signal Connector Circuit Block Diagram User Lines Cable Connection 7User Lines Cable with Ferrite BlockOperation RS-232Operation Command SyntaxManual Conventions Command Format and Parameters FormatFlo ting Point Number floa Order Command StringsCommand Terminators Iset 2.0A VsetCommand Summary DLY? AUXB?CMODE? ERR?IHI FAULT?Idata ILOAUXA? Command ReferenceCmode 1/ON Description AlsoRemote/Local Operation on Chapter Mask None = Unmask ALL ALL, None Command Voltage settings which are being held. See Hold command Accumulated Status, Status, and Fault Registers ASTS?ACF PONREM OPFError0 #ErrorNo ErrorsIdentificationExplanation Error CodesTroubleshooting Diagnostic LEDsEthernet Mode Troubleshooting Tips 10 Ethernet Mode TipsPossibleCauses RS-232Mode Troubleshooting Tips RS-232and/or Ethernet Mode Troubleshooting TipsPage Calibration Calibration Voltage Calibration Setup Voltage Mode CalibrationVoltage Program Calibration Procedure Voltage Readback Calibration Procedure Current Calibration Setup Current Mode CalibrationCurrent Program Calibration Procedure Current Readback Calibration Procedure Over Voltage Protection OVP Calibration Page Specifications 40-30 OVP600-2 40-70 600-4 Page Administration Changing the Root Password Resetting the Configuration from a Browser Resetting the Configuration to DefaultsIntroduction Viewing Port Statistics and Settings Copying the Configuration to and from a ServerViewing Network Statistics NET Interpreting LED InformationDIA Page Warranty and Product Information WarrantyDisclaimer ProductReturn Material Authorization Policy ExclusionsOut of Warranty Service Return ProcedureInformation About Your System Page Xantrex Technology Inc