Xantrex Technology ENET-XFR3 manual Features and Functions, Interface Features

Page 20

Features

CONTROLLER

HUB

Figure 1-1Sample configuration using Ethernet/RS-232 Interface (1200 Watt DC Power Supplies Shown)

Features and Functions

Interface Features

Programmable soft limits for voltage and current

Programmable over voltage protection with reset

Easy-to-use, self-documenting command set

Standardized commands for complete communication with any of the supplies in the system

User-programmable isolated fault, polarity, isolation, and auxiliary, user-defined output signals.

LED status signals: error, address, remote/local operation, and over voltage protection.

Foldback in CV or CC mode with reset

Software calibration

1–2

TM-XR9B-01XN

Image 20
Contents Operating Manual Page XFR 1.2kW and 2.8kW Ethernet/RS-232 Interface Option Date and Revision Audience PurposeScope Organization Conventions Used Related InformationPage Important Safety Instructions Viii Contents Operation Calibration SpecificationsAdvanced Ethernet Administration Xii Figures Xiv Tables Xvi Features DescriptionFeatures and Functions Interface FeaturesReadback Functions Ethernet FeaturesProgrammable Functions Page Configuration IntroductionFor RS-232 Initial Inspection Front Panel SRQERR FLT1Item Ethernet/RS-232 Interface PCB 2Ethernet/RS-232 Interface Jumper Selections XoffProcedure for 1.2kW XFR Changing Internal JumpersProcedure for 2.8kW XFR 1Step#DescriptionActionModeConfigure for Ethernet Basic Setup Procedure EthernetBasic Setup Procedure RS-232 1StepConfiguring for Ethernet or RS-232 EthernetEthernet Communications Ethernet ConnectionLocating the Power Supply on Your Network Configuring Ethernet Bridge Installing and Using RealPort1 BackgroundRS-232Communications RS-232 Connection6Jumper J2 Settings for Baud Rate Baud Rate SelectionFlow Control Selection 7Jumper J2 Flow Control SectionRemote/Local Mode Startup Remote/Local OperationRemote Mode Operation Local Mode Operation Remote Enable REN CommandPower Supply Settings Local Lockout LLO CommandXON/XOFF RTS/CTSAdditional User Options and Settings OVP SelectionHigh LOW OFF TTL Shutdown PolarityLowon User Signals User Lines ConnectorUser Lines Signal Connector Circuit Block Diagram User Lines Cable Connection 7User Lines Cable with Ferrite BlockOperation Manual Conventions Command SyntaxRS-232Operation Command Format and Parameters FormatFlo ting Point Number floa Command Strings Command TerminatorsOrder Iset 2.0A VsetCommand Summary AUXB? CMODE?DLY? ERR?FAULT? IdataIHI ILOCmode 1/ON Command ReferenceAUXA? Description AlsoRemote/Local Operation on Chapter Mask None = Unmask ALL ALL, None Command Voltage settings which are being held. See Hold command Accumulated Status, Status, and Fault Registers ASTS?PON REMACF OPFError0 #ErrorNo ErrorsIdentificationExplanation Error CodesTroubleshooting Diagnostic LEDsEthernet Mode Troubleshooting Tips 10 Ethernet Mode TipsPossibleCauses RS-232Mode Troubleshooting Tips RS-232and/or Ethernet Mode Troubleshooting TipsPage Calibration Calibration Voltage Program Calibration Procedure Voltage Mode CalibrationVoltage Calibration Setup Voltage Readback Calibration Procedure Current Program Calibration Procedure Current Mode CalibrationCurrent Calibration Setup Current Readback Calibration Procedure Over Voltage Protection OVP Calibration Page Specifications 40-30 OVP600-2 40-70 600-4 Page Administration Changing the Root Password Introduction Resetting the Configuration to DefaultsResetting the Configuration from a Browser Viewing Network Statistics Copying the Configuration to and from a ServerViewing Port Statistics and Settings DIA Interpreting LED InformationNET Page Warranty and Product Information WarrantyDisclaimer ProductReturn Material Authorization Policy ExclusionsInformation About Your System Return ProcedureOut of Warranty Service Page Xantrex Technology Inc