Xantrex Technology ENET-XFR3 manual Llo, Mask None = Unmask ALL

Page 63

Command Reference

Table 3-7Command Reference

 

 

Command

Description

LLO

isables the front panel LOCAL switch. When LLO is in effect you can only

 

return to local mode using the GTL command. You can remove the local lockout

 

with the REN command. See also “Remote/Local Operation” on page 2–20.

MASK

isables the supply's previously unmasked operating conditions from setting bits

<mne ics>

in the fault and status registers. See “Accumulated Status, Status, and Fault

 

R gisters” on page 3–17. Mnemonics are separated from each other by commas

 

and may be sent in any order.

 

Mnemonics: CV, CC, OV, OT, SD, FOLD, ERR, PON, REM, ACF, OPF, SNSP

 

Note: UNMASK NONE = MASK ALL (Initial value)

 

MASK NONE = UNMASK ALL

OUT <1/ON>, <0/ Enables or disables the supply’s voltage/current output. The supply will continue to

OFF>

accept new commands while the output is disabled but these will not be

 

implemented until OUT ON or OUT 1 is received. OUT ON is the default setting.

 

When you start the supply in remote mode, the output is enabled.

 

OUT OFF (or OUT 0) also sets the isolation signal on the rear panel user lines

 

connector, li e 3. You can use the to trip external relays to isolate the power supply

 

from the load.

 

Initial value: OUT ON (or OUT 1) for output enabled

 

 

OUT?

Asks for the present enabled/disabled status of the supply’s output voltage/current.

 

Response: OUT 1 output enabled or

 

OUT 0 output disabled

 

 

OVCAL

Causes the master controller to perform automatic calibration of the supply’s over

 

voltage protection circuitry. Set CMODE ON before using this command. Ensure

 

jumper J65 on the Ethernet/RS-232 Interface PCB is connected for remote

 

operation.

 

 

OVSET

Sets the supply’s over voltage protection trip point in volts (default) or in

<voltage>

millivolts. If the trip point is exceeded, or if the trip point value is lower than the

 

present output voltage setting, the supply will ignore the command, turn on the

 

ERR LED, and set the ERR bit in the accumulated status register. Reset with the

 

RST command.

 

Range: 0 to 110% of model maximum output voltage (VMAX)

 

Initial value: 110% of model VMAX

 

 

OVSET?

Asks for the supply’s present over voltage protection limit.

 

Response: OVSET <voltage>

 

 

TM-XR9B-01XN

3–13

Image 63
Contents Operating Manual Page XFR 1.2kW and 2.8kW Ethernet/RS-232 Interface Option Date and Revision Purpose ScopeAudience Organization Related Information Conventions UsedPage Important Safety Instructions Viii Contents Operation Specifications Advanced Ethernet AdministrationCalibration Xii Figures Xiv Tables Xvi Description FeaturesInterface Features Features and FunctionsEthernet Features Programmable FunctionsReadback Functions Page Introduction ConfigurationFor RS-232 Initial Inspection FLT Front PanelSRQ ERR1Item Ethernet/RS-232 Interface PCB Xoff 2Ethernet/RS-232 Interface Jumper SelectionsChanging Internal Jumpers Procedure for 1.2kW XFRProcedure for 2.8kW XFR Basic Setup Procedure Ethernet 1Step#DescriptionActionModeConfigure for Ethernet1Step Basic Setup Procedure RS-232Ethernet Configuring for Ethernet or RS-232Ethernet Connection Ethernet CommunicationsLocating the Power Supply on Your Network Configuring Ethernet Bridge Background Installing and Using RealPort1RS-232 Connection RS-232CommunicationsBaud Rate Selection 6Jumper J2 Settings for Baud Rate7Jumper J2 Flow Control Section Flow Control SelectionRemote/Local Operation Remote/Local Mode StartupRemote Mode Operation Remote Enable REN Command Local Mode OperationRTS/CTS Power Supply SettingsLocal Lockout LLO Command XON/XOFFOVP Selection Additional User Options and SettingsTTL Shutdown Polarity LowonHigh LOW OFF User Lines Connector User SignalsUser Lines Signal Connector Circuit Block Diagram 7User Lines Cable with Ferrite Block User Lines Cable ConnectionOperation Command Syntax RS-232OperationManual Conventions Format Command Format and ParametersFlo ting Point Number floa Iset 2.0A Vset Command StringsCommand Terminators OrderCommand Summary ERR? AUXB?CMODE? DLY?ILO FAULT?Idata IHICommand Reference AUXA?Cmode 1/ON Description AlsoRemote/Local Operation on Chapter Mask None = Unmask ALL ALL, None Command Voltage settings which are being held. See Hold command ASTS? Accumulated Status, Status, and Fault RegistersOPF PONREM ACFError Codes Error0 #ErrorNo ErrorsIdentificationExplanationDiagnostic LEDs Troubleshooting10 Ethernet Mode Tips Ethernet Mode Troubleshooting TipsPossibleCauses RS-232and/or Ethernet Mode Troubleshooting Tips RS-232Mode Troubleshooting TipsPage Calibration Calibration Voltage Mode Calibration Voltage Calibration SetupVoltage Program Calibration Procedure Voltage Readback Calibration Procedure Current Mode Calibration Current Calibration SetupCurrent Program Calibration Procedure Current Readback Calibration Procedure Over Voltage Protection OVP Calibration Page Specifications OVP 40-30600-2 40-70 600-4 Page Administration Changing the Root Password Resetting the Configuration to Defaults Resetting the Configuration from a BrowserIntroduction Copying the Configuration to and from a Server Viewing Port Statistics and SettingsViewing Network Statistics Interpreting LED Information NETDIA Page Warranty Warranty and Product InformationProduct DisclaimerExclusions Return Material Authorization PolicyReturn Procedure Out of Warranty ServiceInformation About Your System Page Xantrex Technology Inc