Specifications

Specifications for XFR 2.8kW with Ethernet/RS-232 Interface Installed

Table A-3XFR 2.8kW 7.5 V to 40 V

ProgramModelsResolution

7.5-300

12-220

20-130

33-85

40-70

Voltage

1.2mV

3.1mV

5.1mV

5.1mV

6.2mV

Current

11.3mA

4.3mA

.6mA

13.0mA

2.2mA

OVP

1.2mV

3.1mV

5.1mV

5.1mV

6.2mV

 

 

 

 

 

 

Program Accuracya

10mV

75mV

75mV

75mV

75mV

Voltage

 

±0.12%

±0.12%

±0.12%

±0.3%

±0.3%

Current

300mA

165mA

120mA

425mA

110mA

 

±0.15%

±0.15%

±0.15%

±0.1%

±0.15%

OVP

75mV

200mV

330mV

330mV

400mV

 

 

 

 

 

 

Readback Resolution

 

 

 

 

 

Voltage

1.2mV

3.14mV

5.1mV

5.1mV

6.2mV

Current

11.3mA

4.3mA

.6mA

13.0mA

2.2mA

 

 

 

 

 

 

Readback Accuracya

10mV

75mV

75mV

75mV

75mV

Voltage

 

±0.12%

±0.12%

±0.2%

±0.3%

±0.3%

Current

300mA

165mA

120mA

425mA

110mA

 

±0.15%

±0.15%

±0.15%

±0.1%

±0.15%

a.Apply accuracy specifications according to the following voltage program accuracy example: Set a model 20-130 power supply to 10 volts.

The expected result will be within the range of 10 volts ± 75mV ± 0.12% of the set voltage of 10 volts.

A–4

TM-XR9B-01XN

Image 86
Contents Operating Manual Page XFR 1.2kW and 2.8kW Ethernet/RS-232 Interface Option Date and Revision Audience PurposeScope Organization Conventions Used Related InformationPage Important Safety Instructions Viii Contents Operation Calibration SpecificationsAdvanced Ethernet Administration Xii Figures Xiv Tables Xvi Features DescriptionFeatures and Functions Interface FeaturesReadback Functions Ethernet FeaturesProgrammable Functions Page Configuration IntroductionFor RS-232 Initial Inspection ERR Front PanelSRQ FLT1Item Ethernet/RS-232 Interface PCB 2Ethernet/RS-232 Interface Jumper Selections XoffProcedure for 1.2kW XFR Changing Internal JumpersProcedure for 2.8kW XFR 1Step#DescriptionActionModeConfigure for Ethernet Basic Setup Procedure EthernetBasic Setup Procedure RS-232 1StepConfiguring for Ethernet or RS-232 EthernetEthernet Communications Ethernet ConnectionLocating the Power Supply on Your Network Configuring Ethernet Bridge Installing and Using RealPort1 BackgroundRS-232Communications RS-232 Connection6Jumper J2 Settings for Baud Rate Baud Rate SelectionFlow Control Selection 7Jumper J2 Flow Control SectionRemote/Local Mode Startup Remote/Local OperationRemote Mode Operation Local Mode Operation Remote Enable REN CommandXON/XOFF Power Supply SettingsLocal Lockout LLO Command RTS/CTSAdditional User Options and Settings OVP SelectionHigh LOW OFF TTL Shutdown PolarityLowon User Signals User Lines ConnectorUser Lines Signal Connector Circuit Block Diagram User Lines Cable Connection 7User Lines Cable with Ferrite BlockOperation Manual Conventions Command SyntaxRS-232Operation Command Format and Parameters FormatFlo ting Point Number floa Order Command StringsCommand Terminators Iset 2.0A VsetCommand Summary DLY? AUXB?CMODE? ERR?IHI FAULT?Idata ILOCmode 1/ON Command ReferenceAUXA? Description AlsoRemote/Local Operation on Chapter Mask None = Unmask ALL ALL, None Command Voltage settings which are being held. See Hold command Accumulated Status, Status, and Fault Registers ASTS?ACF PONREM OPFError0 #ErrorNo ErrorsIdentificationExplanation Error CodesTroubleshooting Diagnostic LEDsEthernet Mode Troubleshooting Tips 10 Ethernet Mode TipsPossibleCauses RS-232Mode Troubleshooting Tips RS-232and/or Ethernet Mode Troubleshooting TipsPage Calibration Calibration Voltage Program Calibration Procedure Voltage Mode CalibrationVoltage Calibration Setup Voltage Readback Calibration Procedure Current Program Calibration Procedure Current Mode CalibrationCurrent Calibration Setup Current Readback Calibration Procedure Over Voltage Protection OVP Calibration Page Specifications 40-30 OVP600-2 40-70 600-4 Page Administration Changing the Root Password Introduction Resetting the Configuration to DefaultsResetting the Configuration from a Browser Viewing Network Statistics Copying the Configuration to and from a ServerViewing Port Statistics and Settings DIA Interpreting LED InformationNET Page Warranty and Product Information WarrantyDisclaimer ProductReturn Material Authorization Policy ExclusionsInformation About Your System Return ProcedureOut of Warranty Service Page Xantrex Technology Inc