4 Calibration

Introduction

WARNING

Exercise caution when using and servicing power supplies. High energy levels can be stored at the output voltage terminals on all power supplies in normal operation. In addition, potentially lethal voltages exist in the power circuit and the output connector of power supplies which are rated at 40V and over. Filter capacitors store potentially dangerous energy for some time after power is removed.

You can calibrate the interface in either Ethernet or RS-232mode by adjusting the signal levels on the interface card so that they correspond to the expected signal levels on the power supply's main assembly. You may need to recalibrate the interface if you replace parts either on the interface board or on the main power supply board, or if the unit falls out of specification due to component aging drifts.

Image 75
Contents Operating Manual Page XFR 1.2kW and 2.8kW Ethernet/RS-232 Interface Option Date and Revision Purpose ScopeAudience Organization Related Information Conventions UsedPage Important Safety Instructions Viii Contents Operation Specifications Advanced Ethernet AdministrationCalibration Xii Figures Xiv Tables Xvi Description FeaturesInterface Features Features and FunctionsEthernet Features Programmable FunctionsReadback Functions Page Introduction ConfigurationFor RS-232 Initial Inspection FLT Front PanelSRQ ERR1Item Ethernet/RS-232 Interface PCB Xoff 2Ethernet/RS-232 Interface Jumper SelectionsChanging Internal Jumpers Procedure for 1.2kW XFRProcedure for 2.8kW XFR Basic Setup Procedure Ethernet 1Step#DescriptionActionModeConfigure for Ethernet1Step Basic Setup Procedure RS-232Ethernet Configuring for Ethernet or RS-232Ethernet Connection Ethernet CommunicationsLocating the Power Supply on Your Network Configuring Ethernet Bridge Background Installing and Using RealPort1RS-232 Connection RS-232CommunicationsBaud Rate Selection 6Jumper J2 Settings for Baud Rate7Jumper J2 Flow Control Section Flow Control SelectionRemote/Local Operation Remote/Local Mode StartupRemote Mode Operation Remote Enable REN Command Local Mode OperationRTS/CTS Power Supply SettingsLocal Lockout LLO Command XON/XOFFOVP Selection Additional User Options and SettingsTTL Shutdown Polarity LowonHigh LOW OFF User Lines Connector User SignalsUser Lines Signal Connector Circuit Block Diagram 7User Lines Cable with Ferrite Block User Lines Cable ConnectionOperation Command Syntax RS-232OperationManual Conventions Format Command Format and ParametersFlo ting Point Number floa Iset 2.0A Vset Command StringsCommand Terminators OrderCommand Summary ERR? AUXB?CMODE? DLY?ILO FAULT?Idata IHICommand Reference AUXA?Cmode 1/ON Description AlsoRemote/Local Operation on Chapter Mask None = Unmask ALL ALL, None Command Voltage settings which are being held. See Hold command ASTS? Accumulated Status, Status, and Fault RegistersOPF PONREM ACFError Codes Error0 #ErrorNo ErrorsIdentificationExplanationDiagnostic LEDs Troubleshooting10 Ethernet Mode Tips Ethernet Mode Troubleshooting TipsPossibleCauses RS-232and/or Ethernet Mode Troubleshooting Tips RS-232Mode Troubleshooting TipsPage Calibration Calibration Voltage Mode Calibration Voltage Calibration SetupVoltage Program Calibration Procedure Voltage Readback Calibration Procedure Current Mode Calibration Current Calibration SetupCurrent Program Calibration Procedure Current Readback Calibration Procedure Over Voltage Protection OVP Calibration Page Specifications OVP 40-30600-2 40-70 600-4 Page Administration Changing the Root Password Resetting the Configuration to Defaults Resetting the Configuration from a BrowserIntroduction Copying the Configuration to and from a Server Viewing Port Statistics and SettingsViewing Network Statistics Interpreting LED Information NETDIA Page Warranty Warranty and Product InformationProduct DisclaimerExclusions Return Material Authorization PolicyReturn Procedure Out of Warranty ServiceInformation About Your System Page Xantrex Technology Inc