Installation and Configuration

Installing and Using RealPort®1

Background

RealPort® software allows you to keep using your existing applications that rely on COM ports and RS-232 links for communication purposes, instead of having to develop TCP/IP based network applications. Installed on a network-enabled PC, RealPort® creates a virtual COM port. As such, your application still thinks it is working with a real serial port, such as COM1. When the application sends data to this serial port, RealPort® ships the data across the network to the Ethernet Bridge in your power supply. By doing this, the network is transparent to your existing application.

Installation

RealPort® can be installed on any PC running Windows NT 4.0,

Windows 2000, or Windows XP.

1.Insert the Xantrex XFR Ethernet Software Utilities CD into your CD drive

2.If the CD does not start automatically, double-click the My Computer icon, double-click the CD icon and then double-click autorun_main.htm.

3.When the menu appears, click Digi RealPort®.

4.Follow the on-screen instructions for proper installation.

Note: RealPort® drivers for UNIX systems are available. Contact your Xantrex representative to obtain these drivers if necessary.

Using RealPort®

Once you have installed the RealPort® driver for your power supply, using it is as simple as running your existing application (such as HyperTerminal, or a custom RS-232 application) and setting the COM port to be the one created by the RealPort® driver for your instrument.

1.RealPort® is a registered trademark of Digi International.

2–16

TM-XR9B-01XN

Image 38
Contents Operating Manual Page XFR 1.2kW and 2.8kW Ethernet/RS-232 Interface Option Date and Revision Audience PurposeScope Organization Conventions Used Related InformationPage Important Safety Instructions Viii Contents Operation Calibration SpecificationsAdvanced Ethernet Administration Xii Figures Xiv Tables Xvi Features DescriptionFeatures and Functions Interface FeaturesReadback Functions Ethernet FeaturesProgrammable Functions Page Configuration IntroductionFor RS-232 Initial Inspection ERR Front PanelSRQ FLT1Item Ethernet/RS-232 Interface PCB 2Ethernet/RS-232 Interface Jumper Selections XoffProcedure for 1.2kW XFR Changing Internal JumpersProcedure for 2.8kW XFR 1Step#DescriptionActionModeConfigure for Ethernet Basic Setup Procedure EthernetBasic Setup Procedure RS-232 1StepConfiguring for Ethernet or RS-232 EthernetEthernet Communications Ethernet ConnectionLocating the Power Supply on Your Network Configuring Ethernet Bridge Installing and Using RealPort1 BackgroundRS-232Communications RS-232 Connection6Jumper J2 Settings for Baud Rate Baud Rate SelectionFlow Control Selection 7Jumper J2 Flow Control SectionRemote/Local Mode Startup Remote/Local OperationRemote Mode Operation Local Mode Operation Remote Enable REN CommandXON/XOFF Power Supply SettingsLocal Lockout LLO Command RTS/CTSAdditional User Options and Settings OVP SelectionHigh LOW OFF TTL Shutdown PolarityLowon User Signals User Lines ConnectorUser Lines Signal Connector Circuit Block Diagram User Lines Cable Connection 7User Lines Cable with Ferrite BlockOperation Manual Conventions Command SyntaxRS-232Operation Command Format and Parameters FormatFlo ting Point Number floa Order Command StringsCommand Terminators Iset 2.0A VsetCommand Summary DLY? AUXB?CMODE? ERR?IHI FAULT?Idata ILOCmode 1/ON Command ReferenceAUXA? Description AlsoRemote/Local Operation on Chapter Mask None = Unmask ALL ALL, None Command Voltage settings which are being held. See Hold command Accumulated Status, Status, and Fault Registers ASTS?ACF PONREM OPFError0 #ErrorNo ErrorsIdentificationExplanation Error CodesTroubleshooting Diagnostic LEDsEthernet Mode Troubleshooting Tips 10 Ethernet Mode TipsPossibleCauses RS-232Mode Troubleshooting Tips RS-232and/or Ethernet Mode Troubleshooting TipsPage Calibration Calibration Voltage Program Calibration Procedure Voltage Mode CalibrationVoltage Calibration Setup Voltage Readback Calibration Procedure Current Program Calibration Procedure Current Mode CalibrationCurrent Calibration Setup Current Readback Calibration Procedure Over Voltage Protection OVP Calibration Page Specifications 40-30 OVP600-2 40-70 600-4 Page Administration Changing the Root Password Introduction Resetting the Configuration to DefaultsResetting the Configuration from a Browser Viewing Network Statistics Copying the Configuration to and from a ServerViewing Port Statistics and Settings DIA Interpreting LED InformationNET Page Warranty and Product Information WarrantyDisclaimer ProductReturn Material Authorization Policy ExclusionsInformation About Your System Return ProcedureOut of Warranty Service Page Xantrex Technology Inc