Cisco Systems Broadband Access Center manual Installing the Device Provisioning Engine

Page 40

Chapter 3 Installing Components

Installing Components Using the CLI

Installing the Device Provisioning Engine

To install the DPE:

Step 1 When the installation program prompts you to select one or more components, press y and Enter at Device Provisioning Engine (y/n/?).

To skip installing an RDU and Network Registrar extension points, enter n and Enter for these options.

For example:

Installation Components

Select one or more components to install BPR.

Regional distribution unit (RDU) (y/n/?) [no] n

Cisco Network Registrar extension points (y/n/?) [no] n

Device Provisioning Engine (DPE) (y/n/?) [yes] y

Key Distribution Center (KDC) (y/n/?) [no] n

The program prompts you to confirm the components that you want to install.

Step 2 Press y and Enter to continue. The program displays a message that it is starting individual component validation. Press Enter to continue

Step 3 When validation is complete, the program prompts you to enter the home directory destination. Validation involves checking to verify that the correct patches have been installed. If they are not, error messages appear on screen.

Step 4 To accept the default home directory destination, /opt/CSCObpr/, press Enter, or enter another directory. For example:

Home Directory Destination

Home Directory Destination [/opt/CSCObpr]

Choosing yes will create the directory during the installation. Choosing no will allow a different directory to be chosen.

The directory /opt/CSCObpr does not exist. Create it? (y/n/?) [yes]

Step 5 When validation is complete, the program prompts you to enter the data directory destination.

Step 6 To accept the default data directory destination, /var/CSCObpr/, press Enter, or enter another directory. For example:

Data Directory Destination

Data Directory Destination [/var/CSCObpr]

Choosing yes will create the directory during the installation. Choosing no will allow a different directory to be chosen.

The directory /var/CSCObpr does not exist. Create it? (y/n/?) [yes]

The program prompts you to confirm the components that you want to install.

Step 7 Press y and Enter to create the directory and continue. The program displays the installation parameters that you selected. For example:

Installation Parameters

This screen shows the installation parameters that you have chosen:

 

Cisco Broadband Access Center for Cable Installation Guide 2.7

3-16

OL-19105-01

Image 40
Contents Cisco Broadband Access Center for Cable Installation Guide Americas HeadquartersPage N T E N T S Validating Extensions Setting Up Voice Technology OL-19105-01 How This Guide Is Organized AudienceThis chapter contains the following sections Document Conventions Section Title DescriptionRelated Documentation Refer to these manuals for additional informationTo support the DPE-590 To support the DPE-2115OL-19105-01 Operating System Requirements JDK Patches for SolarisHardware Requirements Network Registrar RequirementsKDC Patches Min. # Server Servers Server Class Processors MemoryTypes of Installations Min. # Recommended #Preparing to Install Components Broadband Access Center for Cable ComponentsInstallation and Startup Process Item DescriptionItem Description Item Description File System Block Size Broadband Access Center Database RequirementsThis example, the file system device is /dev/dsk/c0t0d0s4 Example output from the df command is as follows Installation ChecklistLarge File Support Installation Installation Using the Graphical User InterfaceInstalling from the Command Line Preparing to Install Components Installation OL-19105-01 Installing Components Installing the Regional Distribution Unit Installing Extensions on a Network Registrar Server Installing Extensions Enter these commands to reload the Network Registrar server Field Name DescriptionValidating Extensions Example KDC Password Installing the Key Distribution CenterLocated Installing Components Using the CLI Installing the Device Provisioning EngineProgram then asks you to confirm the directory OL-19105-01 Installing Network Registrar Extensions Is this correct y/n/q/? yes y ACME.COM Installing the Key Distribution Center Installing Components Installing Components Using the CLI Installing the Device Provisioning Engine Installing Components Installing Components Using the CLI OL-19105-01 Installing in a Lab Environment Installing in a Lab Environment Using the GUI Installing in a Lab Environment Using the CLI KDC Fqdn Dhcp Configuring Network Registrar and a Cmts Interface Cable3/0 Ip address 192.168.5.0Ip dhcp relay information option OL-19105-01 Post-Installation Activities Enabling a Network Registrar Spoofing DNS ServerSave and close the /etc/syslog.conf file Uninstalling Broadband Access CenterSyslog is now ready to receive alerts from Bacc Uninstalling Bacc from the Graphical User Interface Uninstalling Bacc from the Console ModeFollowing is displayed Press Enter to exit the programAppliance Version Solaris DPE DPE-590 DPE-2115Upgrading the RDU Before You BeginUpgrading the Solaris DPE # pkgparam CSCObpr Version Upgrading Hardware DPEs Upgrading Network Registrar Extensions Installed before you start the Bacc agentUpgrading the KDC Migrating the RDU Database Migrating from BaccWhen running this script, use this syntax MigrateDb.sh tempdirOL-19105-01 Connecting the Device Provisioning Engine Hardware DPE Setup SequenceTo do this See this section System displays this user mode prompt Configuring and Running a Terminal Emulation ProgramLogging Configuring a Device Provisioning Engine for Data Configure the current time on the DPE. For example Setting Up Voice Technology Packetcable registration policy-privacy value Debugging Example show dpe command outputControls Available Setting Up a Device Provisioning Engine Debugging Network Registrar Configuration File Example Configuration ScriptsWhere Identifies the username Identifies the password Sample Script for Docsis Modems and ComputersSample Script for Docsis Modems and PacketCable MTAs Administrator’s password Alert messages Installation Solaris Broadband Access CenterChoose Installation Type screen Command line interface Installing components CommandsConfiguration management Documentation Conventions Installation Summary screen 3-3,3-7,3-8,4-3Organization Related documents Domain Name SystemJRun process, detecting KDCSetting up DPEs Installing BACSolaris