Installing the 9E106-06 Module
See the Cautions at the end of this table.
!
CAUTION
|
| Table | |
|
|
| |
Switch | Function | Description | |
|
|
| |
|
| This module stores user entered passwords in NVRAM | |
|
| (Nonvolatile Random Access Memory). To clear these | |
| Clear | passwords, toggle this switch and then reset the module’s | |
8 | processor. Once the module resets, factory default passwords | ||
| |||
| are placed in NVRAM. You can use these default passwords | ||
|
| ||
|
| or, if desired, enter new passwords. To enter new passwords, | |
|
| refer to the Module Local Management User’s Guide. | |
|
|
| |
|
| This module stores user entered parameters such as IP | |
|
| addresses, subnet masks, default gateway, default interface, | |
|
| SNMP traps, bridge configurations and module specific | |
| Clear | configurations in NVRAM. To clear these parameters toggle | |
7 | this switch and then reset the module’s processor. Once the | ||
| |||
| module resets, factory default parameters are placed in | ||
|
| ||
|
| NVRAM. You can use the default parameters or, if desired, | |
|
| enter new parameters. To enter new parameters, refer to the | |
|
| Module Local Management User’s Guide. | |
|
|
| |
|
| This module uses BOOTP (Boot Strap Protocol) to download | |
| Force | new versions of the image file into Flash Memory. This | |
6 | BOOTP | procedure forces image files to be downloaded from the PC | |
| Download | or Workstation, configured to act as the BOOTP server, | |
|
| connected to the EPIM port in the Environmental Module. | |
|
|
| |
5 | Reserved | For Factory Use Only | |
|
|
| |
4 | Reserved | For Factory Use Only | |
|
|
| |
3 | Reserved | For Factory Use Only | |
|
|
| |
2 | Reserved | For Factory Use Only | |
|
|
| |
1 | Reserved | For Factory Use Only | |
|
|
|
Caution: Do not toggle Switch 8 unless you intend to reset the user configured passwords to the factory default settings.
Caution: Do not toggle Switch 7 unless you intend to reset the user parameters to the factory default settings.