Cabletron Systems 9E106-06 manual DC/DC Converter, FNB Interface, I960 Switch, I960 Host

Page 27

Operation

DC/DC Converter

The DC/DC converter converts the 48 VDC on the system power bus to the necessary operating voltages for its host network services module. The diagnostic controller monitors and controls the operation of the DC/DC converter.

FNB Interface

SmartSwitch 9000 modules are designed with one of two attachment policies. One allows dual attachment of a module to either FNB-1 or FNB-2; the second allows dual attachment to both FNB-1 and FNB-2. The 9E106-06 has one dual attachment to the FNB backplane, connecting to either FNB-1 or FNB-2. The module can insert into either the FNB-1 or FNB-2, or bypass both. These flexible configuration options make the SmartSwitch 9000 ideal for networks designed to Bridge/Route multiple lower speed LANs to FDDI and/or networks designed using a FDDI collapsed backbone.

i960 Switch

The i960 Switch Processor is the first of the dual i960 RISC microprocessors built into the 9E106-06 Module. This processor provides the packet forwarding logic and can be configured to run as a layer two bridge, or as a SecureFast switch.

i960 Host

The i960 Host Processor is the second of the dual i960 RISC microprocessors built into the 9E106-06 Module. This processor provides the SNMP protocol stacks to support industry standard MIBs. Additionally, Cabletron enterprise extension MIBs are supported for each media type. Advanced management services, such as the Distributed LAN Monitor, telnet and network address to MAC address mapping, are provided by this i960 processor.

3-3

Image 27
Contents SmartSwitch 9E106-06 Ethernet Switch Module User’s Guide Page Page Vcci Notice FCC NoticeDOC Notice Page Contents Appendix a EPIMs Introduction Features Bridging/SecureFast Switching 9E106-06 Getting Help Related ManualsIntroduction Installing the 9E106-06 Module Installing the 9E106-06 Module Epim Revisions Installing EPIMsEpim Epim Board Revision Installing the EpimInstalling an Epim Reset SwitchReset Switch User-Accessible ComponentsUser-Accessible Components Setting the Module Card DIP SwitchLocation of Module DIP Switch See the Cautions at the end of this table Installing the 9E106-06 Module Six Front Panel Ports OperationSMB-10 Bus System Diagnostic ControllerSystem Management Buses SMB-1 BusI960 Host I960 SwitchDC/DC Converter FNB InterfaceOperation Lanview LEDs Lanview LEDsFunctions of the FNB Receive LED are listed in Table Functions of the Ethernet Receive LEDs are listed in Table Lanview LEDs Memory SafetySpecifications Technical SpecificationsPhysical ServiceDimensions WeightEPIM-T EPIMsEPIM-F1 and EPIM-F2 Transmitter power parameters are listed Table A-2EPIM-F3 EPIM-C Connector Type EPIM-A and EPIM-X AUI PortGrounding Table A-4lists the DB-15 pinouts