Cabletron Systems manual Installing the 9E106-06 Module

Page 15

Chapter 2

Installing the 9E106-06 Module

The 9E106-06 Module may be installed in any of the 14 slots available in the SmartSwitch 9000 chassis. To install the 9E106-06 Module, follow the steps below:

1.Remove the blank panel covering the slot that the module is being mounted in. All other slots must be covered, if modules are not being installed, to ensure proper airflow and cooling.

2.Carefully remove the module from the shipping box. (Save the box and packing materials in the event the module must be reshipped.)

3.Attach one end of the ESD wrist strap packaged with the SmartSwitch 9000 chassis to your wrist. Plug the other end into the jack for the ESD Wrist Strap in the lower right corner of the SmartSwitch 9000 chassis shown in Figure 2-1.

4.Remove the module from the plastic bag. Observe all precautions to prevent damage from Electrostatic Discharge (ESD).

5.Carefully examine the module, checking for damage. If any damage exists, DO NOT install the module. Contact Cabletron Systems Technical Support immediately.

6.Before installing the 9E106-06 Module into the chassis, ensure that the bottom and top plastic tabs are unlocked. Slide the module into an available slot and ensure that the module is between the module guides, as shown in Figure 2-1.Check both the upper and lower tracks. Take care that the module slides in straight and engages the backplane connectors properly. Lock down the top and bottom plastic tabs at the same time, applying even pressure.

2-1

Image 15
Contents SmartSwitch 9E106-06 Ethernet Switch Module User’s Guide Page Page Vcci Notice FCC NoticeDOC Notice Page Contents Appendix a EPIMs Introduction Features Bridging/SecureFast Switching 9E106-06 Getting Help Related ManualsIntroduction Installing the 9E106-06 Module Installing the 9E106-06 Module Epim Revisions Installing EPIMsEpim Epim Board Revision Installing the EpimInstalling an Epim Reset SwitchReset Switch User-Accessible ComponentsUser-Accessible Components Setting the Module Card DIP SwitchLocation of Module DIP Switch See the Cautions at the end of this table Installing the 9E106-06 Module Six Front Panel Ports OperationSMB-10 Bus System Diagnostic ControllerSystem Management Buses SMB-1 BusI960 Host I960 SwitchDC/DC Converter FNB InterfaceOperation Lanview LEDs Lanview LEDsFunctions of the FNB Receive LED are listed in Table Functions of the Ethernet Receive LEDs are listed in Table Lanview LEDs Memory SafetySpecifications Technical SpecificationsPhysical ServiceDimensions WeightEPIM-T EPIMsEPIM-F1 and EPIM-F2 Transmitter power parameters are listed Table A-2EPIM-F3 EPIM-C Connector Type EPIM-A and EPIM-X AUI PortGrounding Table A-4lists the DB-15 pinouts