Operation

System Management Buses

There are two management channels within the SmartSwitch 9000 system: the SMB-1 and the SMB-10. These buses provide out-of-band management and inter- module management communication.

SMB-1 Bus

The SMB-1 is a 1Mbs management bus located within the SmartSwitch 9000. This bus is utilized by all diagnostic controllers in the system, including connectivity modules, power supply modules and the environmental module. The SMB-1 transports inter-chassis information between system components, such as power and environmental information, as well as diagnostic messages. Periodic loop-back tests are performed by all modules that share this bus to ensure the validity of SMB-1. In the event a failure is detected on SMB-1, the SMB-10 may be used as an alternate communication channel.

SMB-10 Bus

The SMB-10 is a 10Mbs management bus located within the SmartSwitch 9000 that is also used for inter-chassis communication of modules, as well as serving as an out-of-band management channel into the SmartSwitch 9000. The SMB-10 is externalized from the chassis via an optional Ethernet Port Interface Module (EPIM) located on the front of the Environmental Module. Through an EPIM connection, full SNMP management of the SmartSwitch 9000 is available out-of- band from user data. Modules which share the SMB-10 bus periodically send out loop-back packets to ensure the validity of SMB-10. In the event a fault is detected on the SMB-10, the SMB-1 can be used as an alternate communication channel by the modules.

System Diagnostic Controller

This diagnostic controller is composed of a Z-80 microprocessor and the supporting logic. The diagnostic controller is designed to control the power-up sequencing of modules, monitor the 9E106-06 input and output power parameters, keep watch over the main Host Processor, as well as monitor the temperature and control the SMB LANVIEW diagnostic LED. Although the diagnostic controller and the main Host Processor can operate independently of each other if needed, they exchange information about each others status and overall module condition. The information gathered by the diagnostic controller is available to the network manager via local/remote management and the LCD located on the Environmental Module. The 9E106-06 has been designed so that in the event of a diagnostic controller fault, the 9E106-06 continues to function.

3-2

Image 26
Contents SmartSwitch 9E106-06 Ethernet Switch Module User’s Guide Page Page FCC Notice Vcci NoticeDOC Notice Page Contents Appendix a EPIMs Introduction Features Bridging/SecureFast Switching 9E106-06 Related Manuals Getting HelpIntroduction Installing the 9E106-06 Module Installing the 9E106-06 Module Installing EPIMs Epim RevisionsInstalling the Epim Epim Epim Board RevisionReset Switch Installing an EpimUser-Accessible Components Reset SwitchSetting the Module Card DIP Switch User-Accessible ComponentsLocation of Module DIP Switch See the Cautions at the end of this table Installing the 9E106-06 Module Operation Six Front Panel PortsSMB-1 Bus System Diagnostic ControllerSystem Management Buses SMB-10 BusFNB Interface I960 SwitchDC/DC Converter I960 HostOperation Lanview LEDs Lanview LEDsFunctions of the FNB Receive LED are listed in Table Functions of the Ethernet Receive LEDs are listed in Table Lanview LEDs Technical Specifications SafetySpecifications MemoryWeight ServiceDimensions PhysicalEPIMs EPIM-TTransmitter power parameters are listed Table A-2 EPIM-F1 and EPIM-F2EPIM-F3 EPIM-C Grounding Connector TypeEPIM-A and EPIM-X AUI Port Table A-4lists the DB-15 pinouts