DIAGnostic:BOOT:COLD

:BOOT:COLD DIAGnostic:BOOT:COLD causes the System Instrument to restart (re-boot). Configurations stored in non-volatile memory and RS-232 configurations are reset to their default states:

• DRAM, NRAM, and RDISk memory segments are cleared

• Serial Interface parameters set to:

BAUD 9600

BITS 8

PARity NONE

SBITs 1

DTR ON

RTS ON

PACE XON

 

Serial 0 Owner = system

 

NOTE

 

Resetting the serial interface parameters takes about 0.01 seconds for the

 

built-in serial port and 0.75 seconds per serial plug-in card. While this is taking

 

place the System Instrument will still respond to serial polls. If you are using a

 

serial poll to determine when the cold boot cycle is complete, you should insert a

 

delay of 1 second per plug-in serial card (E1324) before polling the system

 

instrument. This will prevent incorrectly determining that the system instrument

 

has completed its boot cycle.

 

 

 

Comments

• The System Instrument goes through its power-up self tests.

 

Related Commands: DIAG:BOOT:WARM

Example

Re-booting the System Instrument (cold)

 

 

 

DIAG:BOOT:COLD

force boot