Agilent Technologies E1300B, E1301B Instrument Prompt then press D, Control Sequence Functions

Models: E1300B E1301B 75000 SERIES B

1 244
Download 244 pages 1.94 Kb
Page 70
Image 70

To get a list of the logical addresses used in your mainframe, send the SCPI command VXI:CONF:DLAD? to the System Instrument. Then to determine what instrument is at each logical address, send the command VXI:CONF:DLIS? n for each logical address in the list (where n is a logical address).

Returning to the “Select an To return to the “Select an instrument” prompt, press and hold the CTRL key

Instrument” Prompt then press D.

Control Sequences for The terminal interface provides the keyboard control sequences listed in Table Terminal Interface Functions 3-3. These can be thought of as keyboard short-cuts for compatible terminals

(those which provide menu capability). Only those functions in the table which are shaded, operate for “UNKNOWN” terminal types (those which do not support menus). An “UNKNOWN” terminal type has very limited editing capability. It will not support the EDIT mode for the optional IBASIC interpreter. In the following table, † = IBASIC only, ‡ = Front Panel only.

Table 3-3. Control Sequence Functions

Del char

Delete character at the cursor position

CTRL-X

 

 

 

Clr end

Clears line from cursor position to end of line

CTRL-L

Clear line

Clears line regardless of cursor position

CTRL-U

 

 

 

Insert line †

Inserts a blank line at the cursor position

CTRL-O

 

 

 

Delete line † ‡

Deletes the line at the current cursor position

CTRL-DEL

 

 

 

End of line

Move cursor to the end of current line

CTRL-Z

 

 

 

Start of line

Move cursor to the beginning of current line

CTRL-A

 

 

 

Return

Terminates user entry

CTRL-M

RCL_MENU

Recalls the last command executed via the

CTRL-W

 

menu keys

 

 

 

 

RCL_PREV

Recalls the last several commands executed

CTRL-F

 

via user input

 

 

 

 

RCL_NEXT

After RCL_PREV, RCL_NEXT may be

CTRL-B

 

used to move forward through the recalled

 

 

commands

 

 

 

 

SEL_INST

Return to “Select an instrument” menu

CTRL-D

 

 

 

CLR_INST

Clear instrument’s input and output buffers

CTRL-C

 

 

 

RST_INST

Like CLR_INST plus clears

CTRL-R

 

 

 

3-22 Using the Display Terminal Interface

Page 70
Image 70
Agilent Technologies E1300B, E1301B, 75000 SERIES B user manual Instrument Prompt then press D, Control Sequence Functions