:CONFigure

:HIERarchy?

VXI :CONFigure :HIERarchy?

VXI:CONF:HIER? Returns current hierarchy configuration information about the selected logical address. The individual fields of the response are comma separated. If the information about the selected logical address is not available from the destination device (i.e., the requested device is not in the mainframe) then Error -224 ("parameter error") will be set and no response data will be sent.

NOTE

This command is included in the E1300/E1301 because it is a required SCPI

 

command. Since there are no message based devices in the E1300/E1301, most

 

of these fields will be null valued for the E1300/E1301.

 

 

Comments

• This command returns the following values:

 

Logical address: an integer between -1 and 255 inclusive. -1

 

indicates that the device has no logical address.

 

Commander’s logical address: an integer between -1 and 255

 

inclusive. -1 indicates that the device has no commander or that the

 

commander is unknown. This value is always 0 for the E1300/E1301.

 

Interrupt handlers: a comma separated list of seven integers

 

between 0 and 7 inclusive. Interrupt lines 1–7 are mapped to the

 

individual return values. 0 is used to indicate that the particular

 

interrupt handler is not configured. A set of return values of

 

0,0,0,5,2,0,6 would indicate that:

 

• handler 4 is configured to handle interrupts on line 5

 

• handler 5 is configured to handle interrupts on line 2

 

• handler 7 is configured to handle interrupts on line 6

 

• handlers 1, 2, 3, and 6 are not configured

Interrupters: a comma separated list of seven integers between 0 and 7 inclusive. Interrupt lines 1–7 are mapped to the individual return values. 0 is used to indicate that the particular interrupter is not configured. A set of return values of 0,0,0,5,2,0,6 would indicate that:

interrupter 4 is configured to handle interrupts on line 5

interrupter 5 is configured to handle interrupts on line 2

interrupter 7 is configured to handle interrupts on line 6

interrupters 1, 2, 3, and 6 are not configured

Pass/Failed: an integer which contains the pass/fail status of the specified device encoded as follows:

0 = FAIL, 1 = IFAIL, 2 = PASS, 3 = READY

Manufacturer’s Specific Comments. Up to 80 character string contains manufacturer specific data in string response data format. This field is sent with a 488.2 string response data format, and will contain the instrument name and its IEEE 488.1 secondary address unless a start-up error is detected. In that case, this field will contain one or more error codes in the form "CNFG ERROR: n, m, ...,z" . See Appendix B, Table B-3 for a complete list of these codes.

System Instrument Command Reference 7-57

Page 185
Image 185
Agilent Technologies 75000 SERIES B, E1301B, E1300B user manual VXI CONFigure HIERarchy?