ABORt

SCPI Command

This section describes the SCPI commands for the System Instrument.

Reference

Commands are listed alphabetically by subsystem and also within each

 

subsystem. A command guide is printed in the top margin of each page. The

 

guide indicates the first command listed on that page.

ABORt

The ABORT subsystem is a part of the System Instrument’s trigger system.

 

ABORT resets the trigger system from its Wait For Trigger state to its Idle state

 

and aborts any pacer pulse train in progress. ABORt performs the opposite

 

function of the INITiate:IMMediate command. INITiate enables the trigger

 

system, while ABORt disables it.

Subsystem Syntax

ABORt

Comments

ABORt does not affect any other settings of the trigger system. When the

 

 

INITiate command is sent, the trigger system will respond just as it did

 

 

before the ABORt command was sent.

 

 

Related Commands: INITiate, TRIGger

 

 

*RST Condition: ABORT

 

Example Stopping Pacer pulses with ABORT

 

 

 

TRIG:SOUR HOLD

trigger source is TRIG

 

 

 

command

 

 

SOUR:PULS:COUN 1E3

output 1000 Pacer pulses

 

 

SOUR:PULS:PER .1 S

pulse period set to .1 second

 

 

INIT

go to Wait For Trigger state

 

 

TRIG

trigger the Pacer to output

 

 

 

pulses

 

 

.

 

 

 

.

 

 

 

ABORT

go to Trigger-Idle state and stop

 

 

 

Pacer pulses

7-4 System Instrument Command Reference

Page 132
Image 132
Agilent Technologies E1301B, E1300B, 75000 SERIES B user manual Scpi Command, Reference, ABORt, Abort