SYSTem:COMMunicate :SERial[n] [:RECeive] :PARity :CHECk

:COMMunicate :SERial[n] [:RECeive] :PARity :CHECk

Parameters

Comments

SYSTem:COMMunicate:SERial[n][:RECeive]:PARity:CHECk < check_cntrl>

controls whether or not the parity bit in received serial data frames will be considered significant.

Parameter

Parameter

Range of

Default

Name

Type

Values

Units

 

 

 

 

check_cntrl

boolean

0 1 OFF ON

none

 

 

 

 

When check_cntrl is set to 0 or OFF, received data is not checked for

correct parity. Transmitted data still includes the type of parity configured with … PARity:TYPE .

DIAG:BOOT:COLD will set … CHECk to OFF.

Related Commands: SYST:COMM:SER[n]:PARity:TYPE

*RST Condition: No change

Example Set parity check to ON

 

 

SYST:COMM:SER0:PAR:CHEC ON

 

 

:COMMunicate

 

 

 

 

 

 

 

SYSTem:COMMunicate:SERial[n][:RECeive]:PARity:CHECk? returns the

:SERial[n] [:RECeive]

 

state of parity checking.

 

 

 

:PARity :CHECk?

 

 

 

 

 

 

Example Is parity checking on or off?

 

 

 

 

 

SYST:COMM:SER0:PAR:CHEC?

 

 

 

 

enter statement

statement enters 0 or 1

:COMMunicate:

 

 

 

 

 

 

 

SYSTem:COMMunicate:SERial[n][:RECeive]:PARity[:TYPE] < type>

SERial[n] [:RECeive]

 

Configures the type of parity to be checked for received data, and generated for

:PARity [:TYPE]

 

transmitted data.

 

 

 

Parameters

 

 

 

 

 

 

 

Parameter

Parameter

Range of

Default

 

 

 

Name

Type

Values

Units

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

type

discrete

EVEN ODD ZERO ONE NONE

none

 

Comments

 

• Attempting to set type to other than those values shown will result in an

 

 

error -222.

 

 

 