SYSTem:COMMunicate :SERial[n]:TRANsmit :PACE [:PROTocol]

:COMMunicate SYSTem:COMMunicate:SERial[ n] :TRANsmit:PACE[ :PROTocol]

 

:SERial[n]:TRANsmit

< protocol> enables or disables the transmit pacing (XON/XOFF) protocol.

:PACE [:PROTocol]

 

 

 

 

Parameters

 

 

 

 

Parameter

Parameter

Range of

Default

 

Name

Type

Values

Units

 

 

 

 

 

 

protocol

discrete

XON NONE

none

 

 

 

 

 

Comments

• For an Agilent E1324A, AUTO is always ON. In this case

 

… TRAN:PACE will also set … [RECeive]:PACE

Receipt of an XOFF character (ASCII 1910, 1316) will hold off transmission of data until an XON character (ASCII 1710, 1116) is received.

DIAG:BOOT:COLD will set … PACE to XON.

Related Commands: SYST:COMM:SER[n]:TRAN:AUTo

*RST Condition: No change

Example Set XON/XOFF transmit pacing

 

 

SYST:COMM:SER0:TRAN:PACE:PROT XON

 

 

:COMMunicate

 

 

 

 

 

 

 

SYSTem:COMMunicate:SERial[n]:TRANsmit:PACE[:PROTocol]? returns

:SERial[n] :TRANsmit

 

the current transmit pacing protocol.

 

 

 

 

:PACE [:PROTocol]?

 

 

 

 

 

 

 

 

Example Check transmit pacing protocol

 

 

 

 

 

 

SYST:COMM:SER0:TRAN:PACE:PROT?

 

 

 

 

enter statement

statement enters the string

 

 

 

 

 

"XON" or "NONE"

 

 

:DATE

 

 

 

 

 

 

 

 

SYSTem:DATE < year> ,< month> ,< day> sets the E1300/E1301

 

 

 

 

mainframe’s internal calendar.

 

 

 

 

Parameters

 

 

 

 

 

 

 

 

 

Parameter

Parameter

 

Range of

 

Default

 

 

 

Name

Type

 

Values

 

Units

 

 

 

 

 

 

 

 

 

 

 

 

year

numeric

 

must round to 1980 to 2079

 

none

 

 

 

 

 

 

 

 

 

 

 

 

month

numeric

 

must round to 1 to 12

 

none

 

 

 

 

 

 

 

 

 

 

 

 

day

numeric

 

must round to

 

none

 

 

 

 

 

 

1 through last day of month

 

 

 

Comments

 

• The upper limit on the day parameter is dependent on the month

 

 

 

 

parameter and may be dependent on the year parameter in the case of a

 

 

leap year.

 

 

 

 

 

 