VXI :SELect

:SELect

VXI:SELect < logical_addr> specifies the logical address which is to be used by

 

many subsequent commands in the VXI subsystem.

 

Parameters

 

 

 

 

 

Parameter

Parameter

 

Range of

Default

 

Name

Type

 

Values

Units

 

 

 

 

 

 

 

logical_addr

numeric

 

0 through 255

none

 

 

 

 

 

 

Comments

• The *RST default value for

logical_addr is that no logical address is

 

selected (i.e., -1). All other commands which require a logical address to

 

be selected will respond with Error -221 ("settings conflict") if no logical

 

address is selected.

 

 

 

When a command encounters an Error -240 ("Hardware Error") the equivalent of a *RST is executed. This will cause the selected logical address to be set to -1.

Related Commands: VXI:CONF:LADD?

Example Select a logical address

 

VXI:SEL 64

sets the logical address to be

 

used by subsequent VXI

 

subsystem commands to 64.

:SELect? VXI:SELect? returnsthe logical address which will be used by many subsequent commands in the VXI subsystem. If no logical address has been selected, this query will return -1.

System Instrument Command Reference 7-63

Page 191
Image 191