:COMMunicate :SERial[n] [:RECeive] :SBITs?

Example

SYSTem :COMMunicate :SERial[n] [:RECeive] :SBITs?

SYSTem:COMMunicate:SERial[n][:RECeive]:SBITs? [MIN MAX] returns:

The current stop bit setting if no parameter is sent.

The maximum allowable setting if MAX is sent.

The minimum allowable setting if MIN is sent.

Querying the current stop bit configuration.

 

SYST:COMM:SER0:SBITs?

:REC is implied

enter statement

statement enters 1 or 2

:COMMunicate :SERial[n] :TRANsmit :AUTO

Parameters

SYSTem:COMMunicate:SERial[n]:TRANsmit:AUTO < auto_cntrl> when ON, sets the transmit pacing mode to be the same as that set for receive pacing. When OFF, the transmit pacing mode may be set independently of the receive pacing mode.

Parameter

Parameter

Range of

Default

Name

Type

Values

Units

 

 

 

 

 

 

 

 

auto_cntrl

boolean

0 1 OFF ON

none

Comments

For an Agilent E1324A, AUTO is always ON. Trying to set OFF or 0 will

 

 

generate an error.

 

 

DIAG:BOOT:COLD will set … AUTO to ON.

 

Related Commands: SYST:COMM:SER[n]:REC:PACE:PROT,

 

 

SYST:COMM:SER[n]:TRAN:PACE:PROT

 

*RST Condition: … TRAN:AUTO ON

 

Example Link transmit pacing with receive pacing

 

 

 

SYST:COMM:SER0:TRAN:AUTO ON

 

 

 

:COMMunicate SYSTem:COMMunicate:SERial[n]:TRANsmit:AUTO? returns the current

:SERial[n] :TRANsmit

state of receive to transmit pacing linkage.

 

:AUTO?

 

 

 

Comments

For an Agilent E1324A, AUTO is always ON. In this case … AUTO? will

 

 

always return a 1.

 

Example Is AUTO ON or OFF?

 

 

 

SYST:COMM:SER0:TRAN:AUTO?

 

 

 

enter statement

statement enters the number 1

 

 

 

or 0

System Instrument Command Reference 7-47

Page 175
Image 175