self-test routine results in an error condition, the TEST indicator blinks and the remaining LEDs display a code indicating which specific test was running when the error occurred.

The LED error display uses the top six LEDs on the front panel to create the Diagnostic Code. These codes are binary representations, where ON is a 1 and OFF is a 0. All of the codes and a brief description are listed in Table D-1.

For example, suppose the TEST indicator blinks and the front panel indicators appear as follows:

The first six LEDs represent the Diagnostic Code, which is “100000". According to Table D-1, the error occurred within the ROM Test.

Table 4-1. Diagnostic Code Reference

Code

Test

 

 

0 0 0 0 0 0

CPU

 

 

1 0 0 0 0 0

ROM

 

 

0 1 0 0 0 0

Initial Stack

 

 

D - 2 ONline Ethernet Bridge Module Installation and Operation Guide

Page 230
Image 230
3Com 5102B-EE installation and operation guide Diagnostic Code Reference, Code Test