Table 5-2. Power-Up Self-Test Suggestions
Problem | Troubleshooting Suggestions |
|
|
The test indicator | Press the RESET button on the front panel |
continues blinking. | to restart the |
| result is the same, try the next step. |
|
|
| Make sure the AUI loopback connector or |
| transceiver cable is securely attached to the |
| AUI port. |
|
|
| If transceiver cable is attached to the AUI |
| port, check the following: |
|
|
| ❑ Make sure the transceiver and |
| transceiver cable are compatible (see |
| Appendix C). |
|
|
| ❑ Make sure the transceiver is receiving |
| power through the transceiver cable. |
| Many transceiver models have power |
| indicators. |
|
|
| ❑ Make sure the transceiver is properly |
| connected to the Ethernet/IEEE 802.3 |
| cable. |
|
|
| ❑ Make sure the Ethernet/IEEE 802.3 |
| cable plant is configured correctly, e.g., |
| both ends are terminated with 50 ohms. |
|
|
If all these conditions are met and you still cannot get your Bridge Module to operate, refer to Appendix E for Technical Assistance.
Troubleshooting 5 - 3