Modifying Parameters
Parameter values are stored in
Use the SET command to modify parameter values. You must first type the administrator password when you log in to the management interface. The administrator password provides access to commands that allow you to modify the current bridge configuration.
Once you have entered the administrator password, you can change parameter values using the SET command. Listed below is an example of changing the Bridge Module terminal baud rate.
OEBM> set terminal baud 1200 [ENTER]
Terminal parameter changed
Once you have made all the parameter changes you want, you may want to issue the SAVE ALL command and then logout of administrator mode to prevent any unauthorized changes.
Saving Parameters
When you reboot the system, all parameters that can be set are reset to their saved values. Therefore, to save the new parameter values you changed and make them effective on the next reboot, you must issue the SAVE command before rebooting. Use the SAVE command to save parameter values for the following groups:
❑All
❑Alert
❑Bridge
❑Community
❑Device
3 - 6 ONline Ethernet Bridge Module Installation and Operation Guide