Table 4-4. SHOW COUNTER PORTS Command Attributes

Attribute

Description

 

 

SQE (Heartbeat) Failures

Number of times the frame was

(You can disable this

transmitted without successful SQE

attribute using the SET

(heartbeat). This is not a fatal error. It

DEVICE SQE_MODE

may occur when SQE is turned off at the

command)

transceiver.

 

 

Transmitter Underflowed

Number of times a frame transmit

 

aborted because the Ethernet Controller

 

could not access memory.

 

 

Late Collisions

Number of collisions after the slot-time of

 

the channel has expired.

 

 

Transmitter Lost Carrier

Number of times a frame was sent and

 

there was an open tap into the Ethernet

 

(AUI port disconnected).

 

 