3Com 5102B-EE installation and operation guide SET Device IPADDRESSPORT1

Models: 5102B-EE

1 246
Download 246 pages 3.16 Kb
Page 123
Image 123

SET DEVICE IP_ADDRESS_PORT1

Use the SET DEVICE IP_ADDRESS_PORT1 command to set the Internet Protocol address for port 1 on the Bridge Module.

Note that this command must be used with caution. If used improperly, it has the potential to disrupt the network.

Format

SET DEVICE IP_ADDRESS_PORT1 {IP address}

Parameter

{IP address} = n.n.n.n

Example

OEBM> set device ip_address_port1 145.36.17.58 [ENTER]

Description

The SET DEVICE IP_ADDRESS_PORT1 command enables you to set the Internet Protocol address for port 1 on the Bridge Module. The internet protocol address is entered as n.n.n.n. (four decimal numbers).

Check with your Network Administrator for the next available IP address that can be assigned to port 1 on your Bridge Module.

The factory default IP address for all Bridge Module ports is the loopback address (127.0.0.1).

Management Commands 4 - 49