SET DEVICE

Use the SET DEVICE command to change the Bridge Module device configuration parameters.

Format

SET DEVICE {parameter}

Parameters

{parameter} = contact default_gateway_port1 default_gateway_port2 diagnostics ip_address_port1 ip_address_port2 location

name password sqe_mode subnet_mask_port1 subnet_mask_port2

Description

The SET DEVICE command enables you change the Bridge Module configuration parameters. To make changes permanent, issue the SAVE DEVICE command. Use the SHOW DEVICE command to display the current configuration information.

Since the parameters you can use with the SET DEVICE command have parameters of their own, the following pages describe each parameter.