Note: The loopback connector must be attached to the AUI port or the self-test will not function properly.

Table 2-4. Power-Up Problem Resolution

Problem

Possible Solutions

 

 

 

All indicators are off

Verify that the concentrator is receiving

 

 

power.

 

 

 

 

 

Press the LED/Channel Check button on the

 

 

ONline Controller Module to check if the

 

 

LEDs light.

 

 

 

 

 

Pull the Bridge Module out using the

 

 

module extractor and re-insert it into the

 

 

concentrator.

 

 

The Test LED is blinking

Your unit failed the power-up self-test.

 

 

Write down the LED blink sequence

 

 

displayed on the front panel and refer to

 

 

Appendix D to identify the error code.

 

 

 

 

 

If you cannot correct the error at your site,

 

 

contact 3Com Customer Support as

 

 

explained in Appendix E.

 

 

 

If these alternatives fail to fix the problem, your unit is malfunctioning. Repack it in the shipping carton and contact your 3Com representative for corrective action.

5.Once the self-test is successful, remove the loopback connector and continue with the installation procedure.

2 - 12 ONline Ethernet Bridge Module Installation and Operation Guide

Page 44
Image 44
3Com 5102B-EE installation and operation guide Power-Up Problem Resolution, Problem Possible Solutions