Cabletron Systems 9E106-06 manual EPIM-F3

Page 37

EPIM-F3

Table A-2. Transmitter Power Parameters

Parameter

Typical Value

Worst

Worst Case

Typical

Case

Budget

Budget

 

 

 

 

 

 

 

50/125 ∝m fiber

-13.0 dBm

-15.0 dBm

13.0 dB

17.5 dB

 

 

 

 

 

62.5/125 ∝m fiber

-10.0 dBm

-12.0 dBm

16.0 dB

20.5 dB

 

 

 

 

 

100/140 ∝m fiber

-7.0 dBm

-9.0 dBm

19.0 dB

23.5 dB

 

 

 

 

 

Error Rate

Better than 10 -10

 

 

 

 

 

 

 

 

NOTE

The transmitter power levels and receive sensitivity levels listed are Peak Power Levels after optical overshoot. A Peak Power Meter must be used to correctly compare the values given above to those measured on any particular port. If Power Levels are being measured with an Average Power Meter, then 3 dBm must be added to the measurement to correctly compare those measured values to the values listed (i.e., -30.5 dBm peak = -33.5 dBm average).

EPIM-F3

The EPIM-F3 supports Single Mode Fiber Optic cabling. It has an internal Cabletron Systems FOT-F™ Fiber Optic Transceiver and is equipped with ST Connectors. Figure A-3shows the EPIM-F3. Specifications for the EPIM-F3 are listed in Table A-3.

The link distance is up to 40 kilometers (max) and 25 kilometers (typical) on single mode fiber-optic cable as specified by ANSI SMF-PMD.

Figure A-3. EPIM-F3

A-3

Image 37
Contents SmartSwitch 9E106-06 Ethernet Switch Module User’s Guide Page Page Vcci Notice FCC NoticeDOC Notice Page Contents Appendix a EPIMs Introduction Features Bridging/SecureFast Switching 9E106-06 Getting Help Related ManualsIntroduction Installing the 9E106-06 Module Installing the 9E106-06 Module Epim Revisions Installing EPIMsEpim Epim Board Revision Installing the EpimInstalling an Epim Reset SwitchReset Switch User-Accessible ComponentsUser-Accessible Components Setting the Module Card DIP SwitchLocation of Module DIP Switch See the Cautions at the end of this table Installing the 9E106-06 Module Six Front Panel Ports OperationSystem Management Buses System Diagnostic ControllerSMB-1 Bus SMB-10 BusDC/DC Converter I960 SwitchFNB Interface I960 HostOperation Lanview LEDs Lanview LEDsFunctions of the FNB Receive LED are listed in Table Functions of the Ethernet Receive LEDs are listed in Table Lanview LEDs Specifications SafetyTechnical Specifications MemoryDimensions ServiceWeight PhysicalEPIM-T EPIMsEPIM-F1 and EPIM-F2 Transmitter power parameters are listed Table A-2EPIM-F3 EPIM-C EPIM-A and EPIM-X AUI Port Connector TypeGrounding Table A-4lists the DB-15 pinouts