Brocade Communications Systems 53-1002580-01 manual Introduction, Overview

Page 15

 

Chapter

Introduction

1

 

 

 

 

In this chapter

Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Network Management Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Description of Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Overview

The Brocade 6910 Ethernet Access Switches are carrier grade access switches that meet the requirements for nonstop networking with Layer 2 services. Each platform provides dual power input for redundancy and has been architected with the state of the art hardware design and field proven operating system for reliability and resiliency. Brocade 6910 switches support multiple fiber or copper configurations on a single switch using a 12 Gigabit combination RJ-45/SFP ports. Brocade 6910 allows the same ports to be configured to connect directly to the customer or as network interface on the service side. This ideally positions the Brocade 6910 at the edge of a broadband access network for Ethernet service demarcation, extension and aggregation.

FIGURE 1 GbE ACCESS RINGS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MLX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6910

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GbE Access

CES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ring

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6910

 

 

6910

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10G Regional Ring

IP/MPLS 6910

CES

MLX

The switches have a 1000BASE-T port for dedicated management access (which can be operated outside the data channel). It has an SNMP-based management agent embedded on the main board, which supports both in-band and out-of-band access using a Web browser, SNMP/RMON, or Telnet.

Brocade 6910 Ethernet Access Switch Hardware Installation Guide

1

53-1002580-01

 

Image 15
Contents Brocade 6910 Ethernet Access Switch Brocade Communications Systems, Incorporated Contents Appendix a Troubleshooting Appendix D 53-1002580-01 Figures Page Tables 53-1002580-01 Supported hardware and software About This DocumentThis chapter AudienceBold text Related publicationsGetting technical help or reporting errors About This Document Overview IntroductionOverview Network Management Options Switch ArchitectureSFP Slots Description of HardwareConsole Port Alarm Interface Port10/100/1000BASE-T Ports 10/100/1000BASE-T Management Port The Craft InterfaceLED Description of Hardware Mbps Port Status / SFP LEDs 1~12 Power Supply SocketsDescription of Hardware Selecting a Site Installing the SwitchEquipment Checklist Package ContentsEthernet Cabling Mounting Desktop or Shelf MountingRack Mounting Attaching the Brackets Grounding the Chassis Installing an Optional SFP TransceiverGrounding Point Connecting to a Power SourceRemove both power cords before servicing Connecting DC PowerTop View Front View Rear View DC Plug Connections Connecting AC Power Connecting to the Console PortSerial Cable Wiring Wiring Map for Serial CableWiring Map for Alarm Cable Connecting to the Alarm PortMinor Alarm Connecting to the Alarm Port Twisted-Pair Devices Connecting Network DevicesConnecting to PCs, Servers, Hubs and Switches Making Network ConnectionsMaking Connections to SFP Transceivers Fiber Optic DevicesTroubleshooting Diagnosing Switch IndicatorsIn-Band Access 53-1002580-01 Cables Twisted-Pair Cable and Pin Assignments10BASE-T/100BASE-TX Pin Assignments Crossover Wiring Straight-Through Wiring1000BASE-T Pin Assignments Cable Testing for Existing Category 5 CableFiber Standards Adjusting Existing Category 5 Cabling to Run 1000BASE-TPhysical Characteristics SpecificationsSwitch Features Management Features StandardsCompliances Immunity SafetyMise EN Garde English / FrenchMise EN Garde Connecteurs RJ-45 conformes aux normes FCC Device Remove both power cords before servicing Page Vorsicht German / Spanish / ChinesePrecaución Vorsicht Gefahr Oder umfallen kann Nota Spanish onlyPrecaución Spanish only Pueda sobrepasar los 65 ºC 149 ºF Para la Categoría 5 RJ45 y los cables de fibra óptica Spanish only Chinese Traditional Kg 7.5 lbs 重量 ISO/IEC 8802-3 CSMA/CD 使用托架安裝套件所附的螺絲,將托架安裝至裝置。 使用四顆機架安裝螺絲 未隨附 ,將裝置安裝至機架。 300 253 。 將外接的饋電及電源接地 / 回線,連接至下圖所示的 DC 插頭 交換器隨附 。在機箱正面、DC 電源接線板的上 18 AWG、標示 VW-1 及額定最小 90C。 Chinese Traditional Taiwan Bsmi Statement China-CCC Warning statements Chinese SimplifiedChinese Simplified 10BASE-T GlossaryCSMA/CD LED UTP Numerics Index53-1002580-01