Extron electronic MLC 52 manual Installation Steps

Page 14

CConfiguration switches — When set to On, these DIP switches place the MLC in IR learning or data transfer mode, or disable IR repeats.

Switch 1: Enables IR learning.

Switch 2: Enables data transfer, such as cloning the current MLC configuration onto another MLC 52 (see Configuring Using IR Data Transfer (IR Beaming) on page 15).

Switch 3: Disables IR repeats during playback. For most applications, this switch is placed in the off position.

Switch 4 is not used.

DVolume control (VC models only) connector — Connect an amplifier such as the Extron MPA 152 or a PoleVault switcher to this direct-insertion captive screw connector to enable the volume control knob on the MLC 52 VC front panel to raise and lower the volume on the display device via the amplifier or switcher.

NOTE: This port must be connected only to an Extron device such as a

PoleVault® PVS switcher, an MP Series microphone-to-line preamplifier, or an

MPA Series audio amplifier.

EDisplay control and power connector — This shared six-pole, 3.5 mm captive screw connector is used for IR and RS-232 control of the display device and for DC power (see Wiring the Control Connector on page 12 for information on how to connect supported devices to the MLC).

NOTE: The RS-232 projector control port is present on this connector but not functional on the IR models. The port is functional only on the RS models.

FIR Learning indicators — Each button on the MLC front panel has four memory blocks, which can be programmed with up to four IR (or RS-232) commands. The IR Learning indicator LEDs provide visual feedback indicating the following:

Which of the four memory blocks contains a command

Which of the four memory blocks is ready to be programmed or configured

The IR learning status of the controller

See Configuring Using IR Learning on page 18 for details.

Installation Steps

ATTENTION:

Installation and service must be performed by authorized personnel only. UL listed electrical boxes are recommended.

If using an electrical box, ensure that it is grounded properly.

To install and set up the MLC:

1.If applicable, prepare the installation site (see Mounting the MLC 52 on page 23 and Mounting an Electrical Box on page 63; or see the instructions provided with the optional faceplate, mounting device, or electrical box).

2.Make and install button labels as desired (see Replacing Button Labels on page 10).

MLC 52 MediaLink Controllers • Installation and Configuration

8

Image 14
Contents MLC 52 Series Safety Instructions Safety Instructions English Chinese Simplified(简体中文)FCC Class a Notice TrademarksConventions Used in this Guide Specifications AvailabilitySoftware Commands NotificationsContents Serial Communication Reference InformationAbout the MLC 52 Series MediaLink Controllers IntroductionAbout this Guide ModelsMK models Standard FeaturesEuropean models Options and Accessories MLC 52 Configuration SoftwareSystem Requirements Application DiagramsDevice Drivers MLC 52 RS VC MLC Installation ConfigurationRear Panel and Cable Connections MLC 52 RS MK VC MLC 52 RS MK and MLC 52 RS MK VC Rear Views MLC 52 RS EU and MLC 52 RS EU VC Rear ViewsInstallation Steps Replacing the Faceplate US Models Only Replacing Button Labels Screws to Remove from the MLC FaceplateRemoving and Replacing a Button Label Wiring the Control Connector Wiring for RS-232 Control RS Models OnlyWiring for IR Control Wiring an IRL Wiring an IRLConfiguring Using IR Data Transfer IR Beaming Configuring the MLC 52 Using IRWiring the Power Connector Data Transfer Order in which the Buttons Blink during Data Transfer Percent Complete MLC 52 Models MLC 52 VC Models Buttons LitConfiguring Using IR Learning Activation of LEDs During Button ConfigurationRemoving IR Commands from a Button Setting Up Button Macros Using IR Setting Up an MLC 52 VC Model with an Extron Amplifier Wiring the VC PortRequirements for the MLC 52 VC Extron MPAPreparing the Site Configuring the MLC 52 IR VC and MLC 52 RS VC Vol ButtonsMounting the MLC Mounting the MLC to an Electrical Box Mounting the MLC to a Decora Mounting Bracket Mounting the MLC 52 to an Electrical BoxMounting the MLC to a Wall or Furniture Mounting an MLC 52 to a Decora Mounting BracketOperation Front Panel FeaturesSwitch modes Buttons on the Front PanelFront Panel Components MLC 52 IR and RS MLC 52 IR VC and RS VCMLC 52 RS Mkmlc 52 RS MK VC Mm TRS Cable for the Configuration Port Selecting Inputs Input Selection Buttons on the MLC 52 Front PanelResetting Locking the Front Panel Executive ModeApplication 1 Using Multiple Sources with an MLC Special ApplicationsExamples of Projector Remote Control Types a and B Programming Buttons for an IR Controlled SystemProjector remote control type a application Standard MLC 52 models with a type a remote controlProjector remote control type B application MLC 52 VC models with a type a remote controlStandard MLC 52 with a type B remote control Turn Power OFF? Yes Press Again No Please Wait Programming RGB inputs projector remote control type a Programming video inputs projector remote control type a Projector Remote Type a Using the PC button RGB Using the Video button S-video or composite videoProgramming RGB inputs projector remote control type B Programming video inputs projector remote control type BProjector Remote Type B Using the PC button RGB Serial Communication Configuration PortsUsing the MLC 52/DVCM 50 Configuration Program Installing the Software from the DVD Extron Software DVD ScreenDownloading and Installing the Software from the Website Control Software Button on Download Center ScreenStarting the Configuration Program Select a Comm Port TabMLC 52/DVCM 50 Configuration Program Window Loading Extron Drivers Loading the serial RS-232 driversDownloading IR drivers from the DVD Selecting the MLC 52/DVCM 50 IR Driver PackageIR Device Drivers Package List To download a single driver Saving a Single Driver to the ComputerDownloading drivers from the website Device Drivers ScreenEntering MLC 62 Driver Search Criteria Error Responses Using SIS CommandsUsing the Command and Response Table Host-to-Controller CommunicationsSymbol Definitions Command and Response Table for SIS Commands Reference Information Part Numbers and AccessoriesIncluded Parts Replacement Part Number Included PartsOptional Accessories Recommended CablesMounting an Electrical Box Templates for MLC 52 and MLC 52 VC US Models Attaching an Electrical Box to a Wall StudMLC MLC 52 VC Surface CUT-OUT Area For Furniture Mount 50 8.90 cm 40 cm Extron Warranty