Extron electronic MLC 52 manual Introduction, About this Guide, Models, US models

Page 7

Introduction

This section gives an overview of the MLC 52 User Guide and describes the Extron®

MLC 52 Series MediaLink® Controllers and their features. Topics include:

About this Guide

About the MLC 52 Series MediaLink Controllers

Application Diagrams

About this Guide

This guide contains detailed information and best practice recommendations about cabling, programming, and configuring the MLC 52 Series MediaLink Controllers and provides specifications and dimensions.

Throughout this guide the MLC 52 controllers are referred to as “MLC 52,” “MLC,” “MLC series,” or “controller.”

About the MLC 52 Series MediaLink Controllers

The MLC 52 Series enable RS-232 or infrared (IR) remote control of a projector or other display device. They are economical, compact (one-gang or two-gang size), easy-to-use controllers for use with audio/video equipment in sites such as elementary or high school classrooms or small conference rooms. The MLC 52 acts as a universal remote control panel, providing control of the power, input selection, volume, and other functions of a display device. Device control is provided via the MLC front panel buttons or via a host computer or control system using RS‑232 communication and the Extron Simple Instruction Set (SIS) commands or the Extron MLC 52/DVCM 50 Configuration Program.

The MLC 52 can be configured using three different methods:

IR learning

IR data transfer (“beaming”) from another MLC 52

Using Extron device control drivers with the MLC 52 configuration software program

Models

US models

MLC 52 IR One-gang size. Controls the display device by IR.

MLC 52 IR VC Two-gang size. Controls the display device via IR. This model has a volume control knob to control an amplifier such as the Extron MPA Mini Power Amplifier (purchased separately).

MLC 52 RS One-gang size. Controls the display device by either IR or RS-232.

MLC 52 RS VC Two-gang size. Controls the display device by either IR or RS-232. This model has a volume control knob to control an amplifier such as an Extron MPA Mini Power Amplifier (purchased separately).

MLC 52 MediaLink Controllers • Introduction

1

Image 7
Contents MLC 52 Series Safety Instructions English Chinese Simplified(简体中文) Safety InstructionsTrademarks FCC Class a NoticeNotifications Specifications AvailabilitySoftware Commands Conventions Used in this GuideContents Reference Information Serial CommunicationModels IntroductionAbout this Guide About the MLC 52 Series MediaLink ControllersEuropean models Standard FeaturesMK models MLC 52 Configuration Software Options and AccessoriesDevice Drivers Application DiagramsSystem Requirements MLC 52 RS VC Rear Panel and Cable Connections Installation ConfigurationMLC MLC 52 RS EU and MLC 52 RS EU VC Rear Views MLC 52 RS MK VC MLC 52 RS MK and MLC 52 RS MK VC Rear ViewsInstallation Steps Replacing the Faceplate US Models Only Screws to Remove from the MLC Faceplate Replacing Button LabelsRemoving and Replacing a Button Label Wiring for RS-232 Control RS Models Only Wiring the Control ConnectorWiring for IR Control Wiring an IRL Wiring an IRLWiring the Power Connector Configuring the MLC 52 Using IRConfiguring Using IR Data Transfer IR Beaming Data Transfer Percent Complete MLC 52 Models MLC 52 VC Models Buttons Lit Order in which the Buttons Blink during Data TransferActivation of LEDs During Button Configuration Configuring Using IR LearningRemoving IR Commands from a Button Setting Up Button Macros Using IR Wiring the VC Port Setting Up an MLC 52 VC Model with an Extron AmplifierExtron MPA Requirements for the MLC 52 VCMounting the MLC Configuring the MLC 52 IR VC and MLC 52 RS VC Vol ButtonsPreparing the Site Mounting the MLC to an Electrical Box Mounting the MLC 52 to an Electrical Box Mounting the MLC to a Decora Mounting BracketMounting an MLC 52 to a Decora Mounting Bracket Mounting the MLC to a Wall or FurnitureButtons on the Front Panel Front Panel FeaturesSwitch modes OperationMLC 52 IR and RS MLC 52 IR VC and RS VC Front Panel ComponentsMLC 52 RS Mkmlc 52 RS MK VC Mm TRS Cable for the Configuration Port Input Selection Buttons on the MLC 52 Front Panel Selecting InputsLocking the Front Panel Executive Mode ResettingSpecial Applications Application 1 Using Multiple Sources with an MLCProgramming Buttons for an IR Controlled System Examples of Projector Remote Control Types a and BStandard MLC 52 models with a type a remote control Projector remote control type a applicationMLC 52 VC models with a type a remote control Projector remote control type B applicationStandard MLC 52 with a type B remote control Turn Power OFF? Yes Press Again No Please Wait Programming RGB inputs projector remote control type a Programming video inputs projector remote control type a Projector Remote Type a Using the Video button S-video or composite video Using the PC button RGBProgramming video inputs projector remote control type B Programming RGB inputs projector remote control type BProjector Remote Type B Using the PC button RGB Using the MLC 52/DVCM 50 Configuration Program Configuration PortsSerial Communication Extron Software DVD Screen Installing the Software from the DVDControl Software Button on Download Center Screen Downloading and Installing the Software from the WebsiteSelect a Comm Port Tab Starting the Configuration ProgramMLC 52/DVCM 50 Configuration Program Window Loading the serial RS-232 drivers Loading Extron DriversSelecting the MLC 52/DVCM 50 IR Driver Package Downloading IR drivers from the DVDIR Device Drivers Package List Saving a Single Driver to the Computer To download a single driverDevice Drivers Screen Downloading drivers from the websiteEntering MLC 62 Driver Search Criteria Host-to-Controller Communications Using SIS CommandsUsing the Command and Response Table Error ResponsesSymbol Definitions Command and Response Table for SIS Commands Included Parts Part Numbers and AccessoriesIncluded Parts Replacement Part Number Reference InformationRecommended Cables Optional AccessoriesMounting an Electrical Box Attaching an Electrical Box to a Wall Stud Templates for MLC 52 and MLC 52 VC US ModelsMLC MLC 52 VC Surface CUT-OUT Area For Furniture Mount 50 8.90 cm 40 cm Extron Warranty