Extron electronic manual MLC 52/DVCM 50 Configuration Program Window

Page 56

3.On the Select a Comm Port tab, select a COM port from the drop-down menu, or

On the Emulation Mode tab, select one of the following radio buttons:

Start New Configuration to create a new configuration in emulation mode

Load existing configuration from to open an existing configuration. If you select this radio button, do the following:

a.Click the Browse button.

b.In the Import configuration from... window, locate the configuration file that you want to open in emulation mode (configuration files have a .mlk ending) and double-click on it.

The path to the selected configuration is displayed in the Browse field on the Connection window.

See the MLC 52/DVCM 50 Configuration Program help file for information on using emulation mode.

4.Click OK. The MLC 52/DVCM 50 Configuration Program window opens.

Figure 47. MLC 52/DVCM 50 Configuration Program Window

For an explanation of all procedures for creating MLC 52 configurations, see the configuration program help file. To access the help, select Contents from the Help menu on the MLC 52 window, or press <F1> and navigate to the relevant section.

MLC 52 MediaLink Controllers • Serial Communication

50

Image 56
Contents MLC 52 Series Safety Instructions Safety Instructions English Chinese Simplified(简体中文)FCC Class a Notice TrademarksSpecifications Availability Software CommandsConventions Used in this Guide NotificationsContents Serial Communication Reference InformationIntroduction About this GuideAbout the MLC 52 Series MediaLink Controllers ModelsMK models Standard FeaturesEuropean models Options and Accessories MLC 52 Configuration SoftwareSystem Requirements Application DiagramsDevice Drivers MLC 52 RS VC MLC Installation ConfigurationRear Panel and Cable Connections MLC 52 RS MK VC MLC 52 RS MK and MLC 52 RS MK VC Rear Views MLC 52 RS EU and MLC 52 RS EU VC Rear ViewsInstallation Steps Replacing the Faceplate US Models Only Replacing Button Labels Screws to Remove from the MLC FaceplateRemoving and Replacing a Button Label Wiring the Control Connector Wiring for RS-232 Control RS Models OnlyWiring for IR Control Wiring an IRL Wiring an IRLConfiguring Using IR Data Transfer IR Beaming Configuring the MLC 52 Using IRWiring the Power Connector Data Transfer Order in which the Buttons Blink during Data Transfer Percent Complete MLC 52 Models MLC 52 VC Models Buttons LitConfiguring Using IR Learning Activation of LEDs During Button ConfigurationRemoving IR Commands from a Button Setting Up Button Macros Using IR Setting Up an MLC 52 VC Model with an Extron Amplifier Wiring the VC PortRequirements for the MLC 52 VC Extron MPAPreparing the Site Configuring the MLC 52 IR VC and MLC 52 RS VC Vol ButtonsMounting the MLC Mounting the MLC to an Electrical Box Mounting the MLC to a Decora Mounting Bracket Mounting the MLC 52 to an Electrical BoxMounting the MLC to a Wall or Furniture Mounting an MLC 52 to a Decora Mounting BracketFront Panel Features Switch modesOperation Buttons on the Front PanelFront Panel Components MLC 52 IR and RS MLC 52 IR VC and RS VCMLC 52 RS Mkmlc 52 RS MK VC Mm TRS Cable for the Configuration Port Selecting Inputs Input Selection Buttons on the MLC 52 Front PanelResetting Locking the Front Panel Executive ModeApplication 1 Using Multiple Sources with an MLC Special ApplicationsExamples of Projector Remote Control Types a and B Programming Buttons for an IR Controlled SystemProjector remote control type a application Standard MLC 52 models with a type a remote controlProjector remote control type B application MLC 52 VC models with a type a remote controlStandard MLC 52 with a type B remote control Turn Power OFF? Yes Press Again No Please Wait Programming RGB inputs projector remote control type a Programming video inputs projector remote control type a Projector Remote Type a Using the PC button RGB Using the Video button S-video or composite videoProgramming RGB inputs projector remote control type B Programming video inputs projector remote control type BProjector Remote Type B Using the PC button RGB Serial Communication Configuration PortsUsing the MLC 52/DVCM 50 Configuration Program Installing the Software from the DVD Extron Software DVD ScreenDownloading and Installing the Software from the Website Control Software Button on Download Center ScreenStarting the Configuration Program Select a Comm Port TabMLC 52/DVCM 50 Configuration Program Window Loading Extron Drivers Loading the serial RS-232 driversDownloading IR drivers from the DVD Selecting the MLC 52/DVCM 50 IR Driver PackageIR Device Drivers Package List To download a single driver Saving a Single Driver to the ComputerDownloading drivers from the website Device Drivers ScreenEntering MLC 62 Driver Search Criteria Using SIS Commands Using the Command and Response TableError Responses Host-to-Controller CommunicationsSymbol Definitions Command and Response Table for SIS Commands Part Numbers and Accessories Included Parts Replacement Part NumberReference Information Included PartsOptional Accessories Recommended CablesMounting an Electrical Box Templates for MLC 52 and MLC 52 VC US Models Attaching an Electrical Box to a Wall StudMLC MLC 52 VC Surface CUT-OUT Area For Furniture Mount 50 8.90 cm 40 cm Extron Warranty
Related manuals
Manual 124 pages 24.39 Kb