Extron electronic MLC 52 manual Removing IR Commands from a Button

Page 25

4.Hold the remote control of the display device between 4 and 14 inches (10 to 36 cm) away from the MLC and point it at the IR Transmit/Receive LEDs on the MLC. Within 5 seconds of pressing the MLC button (step 3), press the button on the remote control whose function you want the selected MLC button to learn.

NOTE: For repeating command codes, such as those that increment and decrement a function (for example, turning the volume up and down), hold the button on the projector remote control for at least 3 seconds.

If no IR command is detected within 5 seconds, the LEDs and the front panel button time out and stop blinking.

If the IR code was learned, the rear panel LEDs blink rapidly in succession from the top down, then back up to the top.

If the IR code was not learned, the rear panel LEDs blink in random order.

5.If you do not want to program additional commands on the button, repeat steps 3 and 4 for the next button that you want to program.

If you want to program another command to the same button, press the button again (you can program up to four commands on one button). The next IR learning LED on the rear panel begins flashing (for example, if you have already programmed two commands on this button, the third LED from the bottom flashes).

6.When you are finished programming buttons on the MLC, set configuration switch 1 on the rear panel to Off (down).

7.Press the buttons that you configured to verify that the commands you entered have been learned. If you have an IR Emitter connected on the IR output, it should blink (see Wiring for IR Control on page 13).

Removing IR Commands from a Button

If you want to delete a command that has been programmed onto a button, you must remove all the commands programmed to that button as follows:

1.While the MLC 52 is powered on, set configuration switch 1 to On (up).

2.Press the button for which you want to delete commands, then within 2 seconds press the same button again. The IR learning LEDs turn off.

3.Verify that all commands were erased from the button by pressing the same button again. If the commands have been erased, only LED 1 (the bottom LED) blinks; the other LEDs remain off.

4.When finished removing commands, set switch 1 to Off (down).

MLC 52 MediaLink Controllers • Installation and Configuration

19

Image 25
Contents MLC 52 Series Safety Instructions English Chinese Simplified(简体中文) Safety InstructionsTrademarks FCC Class a NoticeSoftware Commands Specifications AvailabilityConventions Used in this Guide NotificationsContents Reference Information Serial CommunicationAbout this Guide IntroductionAbout the MLC 52 Series MediaLink Controllers ModelsEuropean models Standard FeaturesMK models MLC 52 Configuration Software Options and AccessoriesDevice Drivers Application DiagramsSystem Requirements MLC 52 RS VC Rear Panel and Cable Connections Installation ConfigurationMLC MLC 52 RS EU and MLC 52 RS EU VC Rear Views MLC 52 RS MK VC MLC 52 RS MK and MLC 52 RS MK VC Rear ViewsInstallation Steps Replacing the Faceplate US Models Only Screws to Remove from the MLC Faceplate Replacing Button LabelsRemoving and Replacing a Button Label Wiring for RS-232 Control RS Models Only Wiring the Control ConnectorWiring for IR Control Wiring an IRL Wiring an IRLWiring the Power Connector Configuring the MLC 52 Using IRConfiguring Using IR Data Transfer IR Beaming Data Transfer Percent Complete MLC 52 Models MLC 52 VC Models Buttons Lit Order in which the Buttons Blink during Data TransferActivation of LEDs During Button Configuration Configuring Using IR LearningRemoving IR Commands from a Button Setting Up Button Macros Using IR Wiring the VC Port Setting Up an MLC 52 VC Model with an Extron AmplifierExtron MPA Requirements for the MLC 52 VCMounting the MLC Configuring the MLC 52 IR VC and MLC 52 RS VC Vol ButtonsPreparing the Site Mounting the MLC to an Electrical Box Mounting the MLC 52 to an Electrical Box Mounting the MLC to a Decora Mounting BracketMounting an MLC 52 to a Decora Mounting Bracket Mounting the MLC to a Wall or FurnitureSwitch modes Front Panel FeaturesOperation Buttons on the Front PanelMLC 52 IR and RS MLC 52 IR VC and RS VC Front Panel ComponentsMLC 52 RS Mkmlc 52 RS MK VC Mm TRS Cable for the Configuration Port Input Selection Buttons on the MLC 52 Front Panel Selecting InputsLocking the Front Panel Executive Mode ResettingSpecial Applications Application 1 Using Multiple Sources with an MLCProgramming Buttons for an IR Controlled System Examples of Projector Remote Control Types a and BStandard MLC 52 models with a type a remote control Projector remote control type a applicationMLC 52 VC models with a type a remote control Projector remote control type B applicationStandard MLC 52 with a type B remote control Turn Power OFF? Yes Press Again No Please Wait Programming RGB inputs projector remote control type a Programming video inputs projector remote control type a Projector Remote Type a Using the Video button S-video or composite video Using the PC button RGBProgramming video inputs projector remote control type B Programming RGB inputs projector remote control type BProjector Remote Type B Using the PC button RGB Using the MLC 52/DVCM 50 Configuration Program Configuration PortsSerial Communication Extron Software DVD Screen Installing the Software from the DVDControl Software Button on Download Center Screen Downloading and Installing the Software from the WebsiteSelect a Comm Port Tab Starting the Configuration ProgramMLC 52/DVCM 50 Configuration Program Window Loading the serial RS-232 drivers Loading Extron DriversSelecting the MLC 52/DVCM 50 IR Driver Package Downloading IR drivers from the DVDIR Device Drivers Package List Saving a Single Driver to the Computer To download a single driverDevice Drivers Screen Downloading drivers from the websiteEntering MLC 62 Driver Search Criteria Using the Command and Response Table Using SIS CommandsError Responses Host-to-Controller CommunicationsSymbol Definitions Command and Response Table for SIS Commands Included Parts Replacement Part Number Part Numbers and AccessoriesReference Information Included PartsRecommended Cables Optional AccessoriesMounting an Electrical Box Attaching an Electrical Box to a Wall Stud Templates for MLC 52 and MLC 52 VC US ModelsMLC MLC 52 VC Surface CUT-OUT Area For Furniture Mount 50 8.90 cm 40 cm Extron Warranty