Extron electronic manual Templates for MLC 52 and MLC 52 VC US Models

Page 69

8.Insert the electrical box into the opening, and attach it to the wall stud or furniture with nails or screws, leaving the front edge flush with the outer wall or furniture surface. The following illustration applies to all sizes of electrical boxes.

Wall Stud

Installation

Cable

Cable Clamp

Screws or Nails

Wall opening flush with

edge of box

Figure 53. Attaching an Electrical Box to a Wall Stud

If you are attaching the wall box to wood, use four #8 or #10 screws or 10-penny nails. A minimum of ½ inch (1.3 cm) of screw threads must penetrate the wood.

If you are attaching the wall box to metal studs or furniture, use four #8 or #10 self-tapping sheet metal screws or machine bolts with matching nuts.

If you are using a mounting bracket (mud ring) with the electrical box, see Mounting the MLC to a Decora Mounting Bracket on page 25 to attach the clips that fasten the bracket to the wall or furniture.

9.Ground the MLC to the electrical box as follows:

a.Attach the bare wire end of the provided grounding wire to the Gnd pin of the 6-pole captive screw connector on the MLC rear panel.

b.Attach the other end of the grounding wire to a screw on the junction box.

10.If desired, replace the faceplate or button labels on the MLC (see Replacing the Faceplate (US Models Only) on page 9 or Replacing Button Labels on page 10).

11.Cable and test the MLC before fastening it into the wall box, mounting bracket, or furniture.

Templates for MLC 52 and MLC 52 VC (US Models)

Use these rough-in templates as guides to measure and mark the hole in the wall or furniture through which the MLC 52 will be mounted. The templates provide measurements for installing the controller with either an electrical box or a mounting bracket. You do not need the templates if you are mounting the panel using an external mounting option.

NOTES:

These templates are for US models only.

These templates are not to scale and are provided for reference only.

The MLC controller requires a depth of at least 1.25 inches (3.2 cm) inside the wall or furniture.

MLC 52 MediaLink Controllers • Reference Information

63

Image 69
Contents MLC 52 Series Safety Instructions English Chinese Simplified(简体中文) Safety InstructionsTrademarks FCC Class a NoticeSoftware Commands Specifications AvailabilityConventions Used in this Guide NotificationsContents Reference Information Serial CommunicationAbout this Guide IntroductionAbout the MLC 52 Series MediaLink Controllers ModelsStandard Features European modelsMK models MLC 52 Configuration Software Options and AccessoriesApplication Diagrams Device DriversSystem Requirements MLC 52 RS VC Installation Configuration Rear Panel and Cable ConnectionsMLC MLC 52 RS EU and MLC 52 RS EU VC Rear Views MLC 52 RS MK VC MLC 52 RS MK and MLC 52 RS MK VC Rear ViewsInstallation Steps Replacing the Faceplate US Models Only Screws to Remove from the MLC Faceplate Replacing Button LabelsRemoving and Replacing a Button Label Wiring for RS-232 Control RS Models Only Wiring the Control ConnectorWiring for IR Control Wiring an IRL Wiring an IRLConfiguring the MLC 52 Using IR Wiring the Power ConnectorConfiguring Using IR Data Transfer IR Beaming Data Transfer Percent Complete MLC 52 Models MLC 52 VC Models Buttons Lit Order in which the Buttons Blink during Data TransferActivation of LEDs During Button Configuration Configuring Using IR LearningRemoving IR Commands from a Button Setting Up Button Macros Using IR Wiring the VC Port Setting Up an MLC 52 VC Model with an Extron AmplifierExtron MPA Requirements for the MLC 52 VCConfiguring the MLC 52 IR VC and MLC 52 RS VC Vol Buttons Mounting the MLCPreparing the Site Mounting the MLC to an Electrical Box Mounting the MLC 52 to an Electrical Box Mounting the MLC to a Decora Mounting BracketMounting an MLC 52 to a Decora Mounting Bracket Mounting the MLC to a Wall or FurnitureSwitch modes Front Panel FeaturesOperation Buttons on the Front PanelMLC 52 IR and RS MLC 52 IR VC and RS VC Front Panel ComponentsMLC 52 RS Mkmlc 52 RS MK VC Mm TRS Cable for the Configuration Port Input Selection Buttons on the MLC 52 Front Panel Selecting InputsLocking the Front Panel Executive Mode ResettingSpecial Applications Application 1 Using Multiple Sources with an MLCProgramming Buttons for an IR Controlled System Examples of Projector Remote Control Types a and BStandard MLC 52 models with a type a remote control Projector remote control type a applicationMLC 52 VC models with a type a remote control Projector remote control type B applicationStandard MLC 52 with a type B remote control Turn Power OFF? Yes Press Again No Please Wait Programming RGB inputs projector remote control type a Programming video inputs projector remote control type a Projector Remote Type a Using the Video button S-video or composite video Using the PC button RGBProgramming video inputs projector remote control type B Programming RGB inputs projector remote control type BProjector Remote Type B Using the PC button RGB Configuration Ports Using the MLC 52/DVCM 50 Configuration ProgramSerial Communication Extron Software DVD Screen Installing the Software from the DVDControl Software Button on Download Center Screen Downloading and Installing the Software from the WebsiteSelect a Comm Port Tab Starting the Configuration ProgramMLC 52/DVCM 50 Configuration Program Window Loading the serial RS-232 drivers Loading Extron DriversSelecting the MLC 52/DVCM 50 IR Driver Package Downloading IR drivers from the DVDIR Device Drivers Package List Saving a Single Driver to the Computer To download a single driverDevice Drivers Screen Downloading drivers from the websiteEntering MLC 62 Driver Search Criteria Using the Command and Response Table Using SIS CommandsError Responses Host-to-Controller CommunicationsSymbol Definitions Command and Response Table for SIS Commands Included Parts Replacement Part Number Part Numbers and AccessoriesReference Information Included PartsRecommended Cables Optional AccessoriesMounting an Electrical Box Attaching an Electrical Box to a Wall Stud Templates for MLC 52 and MLC 52 VC US ModelsMLC MLC 52 VC Surface CUT-OUT Area For Furniture Mount 50 8.90 cm 40 cm Extron Warranty
Related manuals
Manual 124 pages 24.39 Kb