Extron electronic MLC 52 manual Mounting an Electrical Box

Page 68

Mounting an Electrical Box

If you want to install the MLC 52 or MLC 52 VC (US models) in an electrical box (in a wall or in furniture), install the box as described below.

NOTE: These instructions are for US models only. To mount an electrical box for an EU or MK model, follow the directions provided with the box by its manufacturer.

1.See the appropriate template diagram in Templates for MLC 52 and

MLC 52 VC (US Models) on page 64, to find out the dimensions of the opening required for the size of the wall box or mud ring that you are using.

2.Using a ruler or tape measure and a soft pencil, draw guidelines on the installation surface (wall or furniture) in the desired orientation and location where the opening for the bracket or wall box will be cut.

ATTENTION: The template diagrams in this guide are not to scale. Do not trace them or use them as patterns on the installation surface. Use these diagrams only for reference to obtain the dimensions of the hole that needs to be cut.

Use a ruler to measure and draw the cutting guidelines.

3.Cut out the wall or furniture material inside the marked area.

4.Check the opening size by inserting the wall box or mounting bracket into the opening. The equipment should fit easily into the opening. Enlarge or smooth the edges of the opening if needed.

5.Feed cables through the electrical box punch-out holes, and secure them with cable clamps to provide strain relief.

6.Ground the electrical box.

7.Exposed cable shields (braided or foil) are potential sources of short circuits. Trim back or insulate shields with heat shrink.

CAUTION: To prevent short circuits, cut back the outer foil shield to the point where the cable exits the cable clamp. Both braided and foil shields should be connected to an equipment ground at the other end of the cable.

MLC 52 MediaLink Controllers • Reference Information

62

Image 68
Contents MLC 52 Series Safety Instructions Safety Instructions English Chinese Simplified(简体中文)FCC Class a Notice TrademarksSpecifications Availability Software CommandsConventions Used in this Guide NotificationsContents Serial Communication Reference InformationIntroduction About this GuideAbout the MLC 52 Series MediaLink Controllers ModelsMK models Standard FeaturesEuropean models Options and Accessories MLC 52 Configuration SoftwareSystem Requirements Application DiagramsDevice Drivers MLC 52 RS VC MLC Installation ConfigurationRear Panel and Cable Connections MLC 52 RS MK VC MLC 52 RS MK and MLC 52 RS MK VC Rear Views MLC 52 RS EU and MLC 52 RS EU VC Rear ViewsInstallation Steps Replacing the Faceplate US Models Only Replacing Button Labels Screws to Remove from the MLC FaceplateRemoving and Replacing a Button Label Wiring the Control Connector Wiring for RS-232 Control RS Models OnlyWiring for IR Control Wiring an IRL Wiring an IRLConfiguring Using IR Data Transfer IR Beaming Configuring the MLC 52 Using IRWiring the Power Connector Data Transfer Order in which the Buttons Blink during Data Transfer Percent Complete MLC 52 Models MLC 52 VC Models Buttons LitConfiguring Using IR Learning Activation of LEDs During Button ConfigurationRemoving IR Commands from a Button Setting Up Button Macros Using IR Setting Up an MLC 52 VC Model with an Extron Amplifier Wiring the VC PortRequirements for the MLC 52 VC Extron MPAPreparing the Site Configuring the MLC 52 IR VC and MLC 52 RS VC Vol ButtonsMounting the MLC Mounting the MLC to an Electrical Box Mounting the MLC to a Decora Mounting Bracket Mounting the MLC 52 to an Electrical BoxMounting the MLC to a Wall or Furniture Mounting an MLC 52 to a Decora Mounting BracketFront Panel Features Switch modesOperation Buttons on the Front PanelFront Panel Components MLC 52 IR and RS MLC 52 IR VC and RS VCMLC 52 RS Mkmlc 52 RS MK VC Mm TRS Cable for the Configuration Port Selecting Inputs Input Selection Buttons on the MLC 52 Front PanelResetting Locking the Front Panel Executive ModeApplication 1 Using Multiple Sources with an MLC Special ApplicationsExamples of Projector Remote Control Types a and B Programming Buttons for an IR Controlled SystemProjector remote control type a application Standard MLC 52 models with a type a remote controlProjector remote control type B application MLC 52 VC models with a type a remote controlStandard MLC 52 with a type B remote control Turn Power OFF? Yes Press Again No Please Wait Programming RGB inputs projector remote control type a Programming video inputs projector remote control type a Projector Remote Type a Using the PC button RGB Using the Video button S-video or composite videoProgramming RGB inputs projector remote control type B Programming video inputs projector remote control type BProjector Remote Type B Using the PC button RGB Serial Communication Configuration PortsUsing the MLC 52/DVCM 50 Configuration Program Installing the Software from the DVD Extron Software DVD ScreenDownloading and Installing the Software from the Website Control Software Button on Download Center ScreenStarting the Configuration Program Select a Comm Port TabMLC 52/DVCM 50 Configuration Program Window Loading Extron Drivers Loading the serial RS-232 driversDownloading IR drivers from the DVD Selecting the MLC 52/DVCM 50 IR Driver PackageIR Device Drivers Package List To download a single driver Saving a Single Driver to the ComputerDownloading drivers from the website Device Drivers ScreenEntering MLC 62 Driver Search Criteria Using SIS Commands Using the Command and Response TableError Responses Host-to-Controller CommunicationsSymbol Definitions Command and Response Table for SIS Commands Part Numbers and Accessories Included Parts Replacement Part NumberReference Information Included PartsOptional Accessories Recommended CablesMounting an Electrical Box Templates for MLC 52 and MLC 52 VC US Models Attaching an Electrical Box to a Wall StudMLC MLC 52 VC Surface CUT-OUT Area For Furniture Mount 50 8.90 cm 40 cm Extron Warranty